Description
In the paper alfa_ka, the temperature coefficient for kappa, parameter seems to have a unit of [mS/m/K] however in the Comsol model given here its unit is [S/m/K]. We think the unit reported in the paper ( [mS/m/K] ) seems to be more likely. However, it is not clear which unit the results shown in the paper belongs to. You may find the exact line of code reporting [S/m/K] unit here:
multiscale-coupling/Battery_model.m
Line 53 in dba3649
| model.param.set('alfa_ka', [num2str(alfa_ka) '[S/m/K]'], 'Temperature coefficient for kappa'); |