| external help file | Module Name | online version | schema |
|---|---|---|---|
Intersight.PowerShell.dll-Help.xml |
Intersight.PowerShell |
2.0.0 |
Fill in the Synopsis
Initialize-IntersightAdapterDceInterfaceSettings [-AdditionalProperties< System.Collections.Generic.Dictionary`2[string,object]>][-ClassId< AdapterDceInterfaceSettings.ClassIdEnum>][-FecMode< AdapterDceInterfaceSettings.FecModeEnum>][-InterfaceId< long>][-ObjectType< AdapterDceInterfaceSettings.ObjectTypeEnum>][-Json< SwitchParameter>][-WithHttpInfo< SwitchParameter>]
Initialize cmdlet is used to instantiate the object of complex type in the Powershell session, it does not create the object on the server.
Type: System.Collections.Generic.Dictionary`2[string,object]
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: FalseThe fully-qualified name of the instantiated, concrete type.\nThis property is used as a discriminator to identify the type of the payload\nwhen marshaling and unmarshaling data.
Type: AdapterDceInterfaceSettings.ClassIdEnum
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: FalseForward Error Correction (FEC) mode setting for the DCE interfaces of the adapter. FEC mode setting is supported only for Cisco VIC 14xx adapters. FEC mode 'cl74' is unsupported for Cisco VIC 1495/1497. This setting will be ignored for unsupported adapters and for unavailable DCE interfaces.\n* cl91 - Use cl91 standard as FEC mode setting. 'Clause 91' aka RS-FEC ('ReedSolomon' FEC) offers better error protection against bursty and random errors but adds latency.\n* cl74 - Use cl74 standard as FEC mode setting. 'Clause 74' aka FC-FEC ('FireCode' FEC) offers simple, low-latency protection against 1 burst/sparse bit error, but it is not good for random errors.\n* Off - Disable FEC mode on the DCE Interface.
Type: AdapterDceInterfaceSettings.FecModeEnum
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: FalseDCE interface id on which settings needs to be configured. Supported values are (0-3).
Type: long
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: FalseThe fully-qualified name of the instantiated, concrete type.\nThe value should be the same as the 'ClassId' property.
Type: AdapterDceInterfaceSettings.ObjectTypeEnum
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True True (ByPropertyName)
Accept wildcard characters: FalseReturns the json payload received in response.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True False
Accept wildcard characters: FalseReturns the HTTP response with headers and content.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: false
Position: Named
Default value: None
Accept pipeline input: True False
Accept wildcard characters: FalseThis cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
PS C:\> Initialize-IntersightAdapterDceInterfaceSettings{ Add example description here }