From d1e987db9db53cac86f3c0ae3eda0625e6f87e13 Mon Sep 17 00:00:00 2001 From: LKuemmel <76958050+LKuemmel@users.noreply.github.com> Date: Fri, 26 Sep 2025 13:23:22 +0200 Subject: [PATCH] Revert "fix auto phase switch for pv charging with min current" --- packages/control/chargepoint/chargepoint.py | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/packages/control/chargepoint/chargepoint.py b/packages/control/chargepoint/chargepoint.py index 2b7a4d8c61..0d403dea61 100644 --- a/packages/control/chargepoint/chargepoint.py +++ b/packages/control/chargepoint/chargepoint.py @@ -920,8 +920,7 @@ def chargemode_support_phase_switch(self) -> bool: control_parameter = self.data.control_parameter pv_auto_switch = ((control_parameter.chargemode == Chargemode.PV_CHARGING or control_parameter.chargemode == Chargemode.ECO_CHARGING) and - (control_parameter.submode == Chargemode.PV_CHARGING or - control_parameter.submode == Chargemode.INSTANT_CHARGING) and + control_parameter.submode == Chargemode.PV_CHARGING and self.data.set.charge_template.data.chargemode.pv_charging.phases_to_use == 0) for p in self.data.set.charge_template.data.chargemode.scheduled_charging.plans: if p.id == self.data.control_parameter.current_plan: