Fix thermal well perforation energy flux#3973
Conversation
|
Hi Nicolas Could you upload the associated model. There is a restriction, probably not documented, where the top segment cannot contain a perforation. |
|
Could you move/change the perf/seg definition so that the top seg doesn't have a perf and then make the comparison. Currently it looks like the top seg has 2 perforations... |
Hello Thomas, I also noticed a MGR issue when the injection starts from 0, I don't know if it is also your case : |
|
Based on discussion with @tjb-ltk, I added an assertion when a perforation is placed on the top well element (wellhead). |
This PR tries to fix a thermal well issue at top perforations.
According to the image below, for a single phase water injection, the temperature drops significantly lower than injection temperature (293.15K ) which is not logical for water injection case (left figure).