1 change: 1 addition & 0 deletions compass/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,7 @@
from .extraction import (
COMPASSGeoHeatPumpExtractor,
COMPASSGeoElectricityExtractor,
COMPASSNaturalGasPipelinesExtractor,
COMPASSGeoRMPExtractor,
COMPASSSmallWindExtractor,
COMPASSSolarExtractor,
Expand Down
1 change: 1 addition & 0 deletions compass/extraction/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,7 @@
# Can drop once plugins register themselves
from .ghp import COMPASSGeoHeatPumpExtractor
from .geothermal_electricity import COMPASSGeoElectricityExtractor
from .natural_gas_pipelines import COMPASSNaturalGasPipelinesExtractor
from .rmp import COMPASSGeoRMPExtractor
from .small_wind import COMPASSSmallWindExtractor
from .solar import COMPASSSolarExtractor
Expand Down
14 changes: 14 additions & 0 deletions compass/extraction/natural_gas_pipelines/__init__.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,14 @@
"""COMPASS natural gas pipelines and compressor stations plugin"""

import importlib.resources

from compass.plugin import create_schema_based_one_shot_extraction_plugin


COMPASSNaturalGasPipelinesExtractor = (
create_schema_based_one_shot_extraction_plugin(
importlib.resources.files("compass.extraction.natural_gas_pipelines")
/ "plugin_config.yaml",
tech="natural_gas_pipelines",
)
)
Original file line number Diff line number Diff line change
@@ -0,0 +1,143 @@
{
"title": "Natural Gas Pipeline and Compressor Station Ordinance Schema",
"description": "One-shot extraction schema focused on stakeholder-priority siting and permitting requirements for natural gas pipelines and compressor stations.",
"version": "2.1.1",
"type": "object",
"required": ["outputs"],
"additionalProperties": false,
"properties": {
"outputs": {
"type": "array",
"items": {
"type": "object",
"required": ["feature", "value", "units", "section", "summary"],
"additionalProperties": false,
"properties": {
"feature": {
"type": "string",
"enum": [
"structures distance",
"front yard distance",
"property lines distance",
"rear yard distance",
"side yard distance",
"residential buildings distance",
"water bodies distance",
"distance between compressor stations",
"noise daytime limit",
"noise nighttime limit",
"zoning districts",
"conditional/special use permit requirement",
"fencing",
"minimum lot size",
"enclosure"
]
},
"value": {
"anyOf": [
{
"type": "number"
},
{
"type": "string"
},
{
"type": "boolean"
},
{
"type": "array",
"items": {
"type": "string"
}
},
{
"type": "null"
}
]
},
"units": {
"type": ["string", "null"]
},
"section": {
"type": ["string", "null"]
},
"summary": {
"type": ["string", "null"]
}
}
}
}
},
"$definitions": {
"setbacks": {
"structures distance": {
"description": "Minimum setback from structures generally for compressor stations or pipeline facilities. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written, such as feet, meters, or miles. IGNORE: setbacks that are explicitly to property lines, yard lines, residential buildings, or water bodies."
},
"front yard distance": {
"description": "Minimum front yard setback for compressor stations or pipeline facilities. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: side-yard, rear-yard, and non-yard setbacks."
},
"property lines distance": {
"description": "Minimum setback from lot lines, parcel lines, tract boundaries, or property lines. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: setbacks explicitly tied to front yard, side yard, rear yard, structures, or water bodies."
},
"rear yard distance": {
"description": "Minimum rear yard setback for compressor stations or pipeline facilities. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: front-yard, side-yard, and non-yard setbacks."
},
"side yard distance": {
"description": "Minimum side yard setback for compressor stations or pipeline facilities. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: front-yard, rear-yard, and non-yard setbacks."
},
"residential buildings distance": {
"description": "Minimum setback from homes, dwellings, occupied residences, or residential buildings. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: residential zoning district setbacks where no building/structure receptor is specified."
},
"water bodies distance": {
"description": "Minimum setback from rivers, streams, lakes, ponds, wetlands, reservoirs, or other water bodies. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: non-distance environmental text or domestic-well-only requirements."
},
"distance between compressor stations": {
"description": "Minimum required distance separating one compressor station from another compressor station. VALUE: numerical minimum distance only. UNITS: source distance units exactly as written. IGNORE: spacing requirements for wells, well pads, or unrelated facilities."
}
},
"noise": {
"noise daytime limit": {
"description": "Daytime noise standard applying to compressor stations or pipeline facilities. VALUE: a numerical maximum decibel limit when stated, or the enforceable ambient-relative threshold phrase when the ordinance uses a day standard without a standalone numeric cap. UNITS: source noise units exactly as written, such as dBA, dB, or dBC, or null when the clause is qualitative only. IGNORE: complaint-response protocol language, health-monitoring programs, and report-submission timelines unless the same clause contains a targeted daytime standard."
},
"noise nighttime limit": {
"description": "Nighttime noise standard applying to compressor stations or pipeline facilities. VALUE: a numerical maximum decibel limit when stated, or the enforceable ambient-relative threshold phrase when the ordinance uses a night standard without a standalone numeric cap. UNITS: source noise units exactly as written, such as dBA, dB, or dBC, or null when the clause is qualitative only. IGNORE: complaint-response protocol language, health-monitoring programs, and report-submission timelines unless the same clause contains a targeted nighttime standard."
}
},
"zoning_and_permitting": {
"zoning districts": {
"description": "Districts where natural gas compressor stations or natural gas pipeline facilities are allowed, conditionally allowed, specially allowed, or prohibited. VALUE: array of district names/codes. UNITS: null. IGNORE: district names mentioned only as setback measurement references unless the same evidence also states use authorization."
},
"conditional/special use permit requirement": {
"description": "Requirement to obtain a conditional use permit, special use permit, special exception, or equivalent discretionary land-use approval. VALUE: array of permit/approval names, or boolean true if required but unnamed. UNITS: null. IGNORE: generic permit administration, fee schedules, and approvals not explicitly tied to compressor stations or pipeline facilities."
}
},
"site_design": {
"fencing": {
"description": "Fencing requirement for compressor stations or pipeline facilities. VALUE: numerical fence height when explicitly stated, otherwise boolean true if fencing is required. UNITS: source distance unit if numerical, otherwise null. IGNORE: security procedures that do not impose a fencing requirement."
},
"minimum lot size": {
"description": "Minimum lot/parcel/site area required for compressor stations or pipeline facilities. VALUE: numerical minimum area only. UNITS: source area units exactly as written, such as acres or square feet. IGNORE: residential lot standards for unrelated uses, permit fees, insurance, hearing logistics, and qualitative lot-platting procedures without numeric area."
},
"enclosure": {
"description": "Requirement to enclose compressor station equipment in a building or structure. VALUE: boolean true if enclosure is required, or numerical only if a specific enclosure dimension threshold is stated. UNITS: source unit if numerical, otherwise null. IGNORE: architectural styling details that do not impose an enforceable enclosure requirement."
}
}
},
"$instructions": {
"scope": "Extract only enacted local requirements explicitly applicable to natural gas compressor stations and natural gas pipeline facilities. Exclude provisions focused only on drilling, fracking, wells, well pads, and unrelated industrial uses unless the same clause explicitly governs compressor stations or pipelines.",
"null_handling": "Use sparse output. Emit rows only for explicitly found in-scope features. Do not emit placeholder rows for missing features. Use null values only when a present targeted feature is qualitative and has no numeric value.",
"verbatim_quotes": "In summary fields, prefer verbatim ordinance text and enclose direct excerpts in double quotation marks.",
"units_discipline": "Do not convert units. Record units exactly as they appear in the ordinance.",
"priority_logic": "Prioritize quantitative build-driving requirements first (setbacks, lot size, day/night noise limits). Preserve targeted ambient-relative noise standards even when the clause does not state a standalone dB cap, and capture the enforceable threshold phrase in value when needed. If a targeted feature is present but only qualitative, capture it with allowed value/units conventions.",
"screening_gate": "If a clause is primarily post-construction complaint protocol, monitoring workflow, administrative reporting, insurance, or hearing process and lacks an explicit targeted numeric requirement or targeted ambient-relative noise standard, do not emit a row."
},
"$qa_checklist": [
"All output rows use only the 15 allowed feature IDs.",
"Numeric setbacks and lot size include numeric values and non-null units when explicitly present.",
"Noise rows capture explicit numeric day/night dB limits and targeted ambient-relative standards.",
"Do not emit complaint-protocol-only noise rows without explicit day/night numeric caps or targeted ambient-relative standards.",
"Zoning districts are arrays of district names/codes.",
"Conditional/special permit rows are tied to explicit discretionary permit language.",
"No off-target extraction from well-only drilling/fracking language."
]
}
112 changes: 112 additions & 0 deletions compass/extraction/natural_gas_pipelines/plugin_config.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,112 @@
schema: ./natural_gas_pipelines_schema.json

data_type_short_desc: natural gas pipeline and compressor station ordinance

cache_llm_generated_content: true

query_templates:
- "{jurisdiction} natural gas compressor station ordinance"
- "{jurisdiction} oil and gas facilities zoning ordinance"
- "{jurisdiction} compressor station setback noise ordinance code"
- "site:ecode360.com {jurisdiction}"
- "site:municode.com {jurisdiction} code of ordinances"

website_keywords:
pdf: 92160
compressor: 46080
pipeline: 46080
"natural gas": 46080
ordinance: 23040
zoning: 11520
setback: 5760
noise: 5760
permit: 2880
"conditional use": 2880
"special use": 2880
enclosure: 1440
fencing: 1440
"code of ordinances": 1440
"municipal code": 1440
ecode360: 1440
municode: 1440
"zoning ordinance": 1440
"ordinance adopted": 720
"land use code": 720
"title xii": 720
county: 360
municipal: 360
chapter: 180
"chapter 205": 180
section: 180

heuristic_keywords:
GOOD_TECH_KEYWORDS:
- compressor
- pipeline
- transmission
- gathering
GOOD_TECH_PHRASES:
- natural gas compressor station
- natural gas pipeline
- compressor station
- gas transmission pipeline
- gas gathering line
- zoning ordinance
- code of ordinances
- municipal code
- ecode360
- pipeline right-of-way
- compressor station noise
- compressor station setback
GOOD_TECH_ACRONYMS:
- ROW
- MAOP
- PHMSA
NOT_TECH_WORDS:
- well pad
- oil well
- gas well
- hydraulic fracturing
- fracking
- drilling permit
- geothermal
- wind turbine
- solar farm
- electric substation
- gas rate tariff
- utility billing
- residential gas appliance

collection_prompts: true
text_extraction_prompts: true

extraction_system_prompt: |-
You are a legal scholar extracting structured data from natural gas
pipeline and compressor station ordinances.

Extract ONLY the following features:
- setbacks from structures, front yard, property lines, rear yard,
side yard, residential buildings, water bodies, and distance between
compressor stations
- daytime and nighttime noise limits
- zoning districts
- conditional/special use permit requirement
- fencing
- minimum lot size
- enclosure

Extract only enacted local requirements that explicitly govern
natural gas compressor stations or natural gas pipeline facilities.
The source ordinance may be a general zoning code, municipal code, or
code of ordinances rather than a technology-specific title.

Do not extract text focused only on wells, drilling, fracking,
utility tariffs/billing, or unrelated industrial uses unless the same
clause directly applies to compressor stations or pipelines.

For noise, ignore complaint-response monitoring protocol details unless
a clause states an explicit numeric day or night dB limit or a targeted
ambient-relative standard that can inform post-processing.

Follow schema feature definitions literally. Keep units exactly as written.
Do not invent values.