98 changes: 0 additions & 98 deletions packages/modules/common/algodue.py

This file was deleted.

44 changes: 40 additions & 4 deletions packages/modules/devices/algodue/algodue/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -30,11 +30,13 @@ def __init__(self,
def update(self):
with self.__tcp_client:

frequency = self.__tcp_client.read_input_registers(0x1038, ModbusDataType.FLOAT_32, unit=self.id)
currents = self.__tcp_client.read_input_registers(0x100E, [ModbusDataType.FLOAT_32]*3, unit=self.id)
powers = self.__tcp_client.read_input_registers(0x1020, [ModbusDataType.FLOAT_32]*3, unit=self.id)
frequency = self.__tcp_client.read_input_registers(0x1038, ModbusDataType.FLOAT_32, unit=self.__modbus_id)
currents = self.__tcp_client.read_input_registers(
0x100E, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
powers = self.__tcp_client.read_input_registers(0x1020, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power = sum(powers)
voltages = self.__tcp_client.read_input_registers(0x1000, [ModbusDataType.FLOAT_32]*3, unit=self.id)
voltages = self.__tcp_client.read_input_registers(
0x1000, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)

imported, exported = self.sim_counter.sim_count(power)

Expand All @@ -51,3 +53,37 @@ def update(self):


component_descriptor = ComponentDescriptor(configuration_factory=AlgodueCounterSetup)

# serial_chars = self.client.read_holding_registers(0x500, [ModbusDataType.UINT_8]*10, unit=self.id)
# model_id = self.client.read_holding_registers(0x505, ModbusDataType.UINT_16, unit=self.id)
# model_string = "unknown"
# if model_id == 0x03:
# model_string = "6 A, 3 phases, 4 wires"
# elif model_id == 0x08:
# model_string = "80 A, 3 phases, 4 wires"
# elif model_id == 0x0c:
# model_string = "80 A, 1 phase, 2 wires"
# elif model_id == 0x10:
# model_string = "40 A, 1 phase, 2 wires"
# elif model_id == 0x12:
# model_string = "63 A, 3 phases, 4 wires"

# type_id = self.client.read_holding_registers(0x506, ModbusDataType.UINT_16, unit=self.id)
# type_string = "unknown"
# if type_id == 0x00:
# type_string = "NO MID, RESET"
# elif type_id == 0x01:
# type_string = "MID"
# elif type_id == 0x02:
# type_string = "NO MID"
# elif type_id == 0x03:
# type_string = "NO MID, Wiring selection"
# elif type_id == 0x05:
# type_string = "MID no varh"
# elif type_id == 0x09:
# type_string = "MID Wiring selection"
# elif type_id == 0x0a:
# type_string = "MID no varh, Wiring selection"
# elif type_id == 0x0b:
# type_string = "NO MID, RESET, Wiring selection"
# meterinfo = "Algodue UEM " + model_string + ", " + type_string