Skip to content
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
24 changes: 9 additions & 15 deletions packages/control/chargepoint/chargepoint.py
Original file line number Diff line number Diff line change
Expand Up @@ -28,7 +28,7 @@
from control.chargemode import Chargemode
from control.chargepoint.chargepoint_data import ChargepointData, ConnectedConfig, ConnectedInfo, ConnectedSoc, Get, Log
from control.chargepoint.chargepoint_template import CpTemplate
from control.chargepoint.control_parameter import ControlParameter, control_parameter_factory
from control.chargepoint.control_parameter import control_parameter_factory
from control.chargepoint.charging_type import ChargingType
from control.chargepoint.rfid import ChargepointRfidMixin
from control.ev.charge_template import ChargeTemplate
Expand Down Expand Up @@ -248,15 +248,6 @@ def setup_values_at_start(self):
self._reset_values_at_start()
self._set_values_at_start()

def reset_control_parameter(self):
""" setzt alle Werte zurück, die während des Algorithmus gesetzt werden.
"""
try:
log.debug(f"ControlParameter an LP {self.num} zurückgesetzt.")
self.data.control_parameter = ControlParameter()
except Exception:
log.exception("Fehler im LP-Modul "+str(self.num))

def set_control_parameter(self, submode: str, required_current: float):
""" setzt die Regel-Parameter, die der Algorithmus verwendet.

Expand Down Expand Up @@ -430,11 +421,14 @@ def check_phase_switch_completed(self):
self.set_state_and_log(message)
return
if self.data.control_parameter.state == ChargepointState.WAIT_FOR_USING_PHASES:
if (phase_switch.phase_switch_thread_alive(self.num) is False and
check_timestamp(self.data.control_parameter.timestamp_charge_start,
charging_ev.ev_template.data.keep_charge_active_duration) is False):
self.data.control_parameter.state = ChargepointState.PHASE_SWITCH_AWAITED
if self._is_phase_switch_required() is False:
if check_timestamp(self.data.control_parameter.timestamp_charge_start,
charging_ev.ev_template.data.keep_charge_active_duration) is False:
if self.cp_ev_chargemode_support_phase_switch():
if phase_switch.phase_switch_thread_alive(self.num) is False:
self.data.control_parameter.state = ChargepointState.PHASE_SWITCH_AWAITED
if self._is_phase_switch_required() is False:
self.data.control_parameter.state = ChargepointState.CHARGING_ALLOWED
else:
self.data.control_parameter.state = ChargepointState.CHARGING_ALLOWED
except Exception:
log.exception("Fehler in der Ladepunkt-Klasse von "+str(self.num))
Expand Down