2 changes: 2 additions & 0 deletions packages/helpermodules/setdata.py
Original file line number Diff line number Diff line change
Expand Up @@ -1016,6 +1016,8 @@ def process_system_topic(self, msg: mqtt.MQTTMessage):
self.__unknown_topic(msg)
elif "/config" in msg.topic:
self._validate_value(msg, "json")
elif "/error_timestamp" in msg.topic:
self._validate_value(msg, float, [(0, float("inf"))])
elif "/get/fault_state" in msg.topic:
self._validate_value(msg, int, [(0, 2)])
elif "/get/fault_str" in msg.topic:
Expand Down
4 changes: 4 additions & 0 deletions packages/helpermodules/subdata.py
Original file line number Diff line number Diff line change
Expand Up @@ -863,12 +863,16 @@ def process_system_topic(self, client: mqtt.Client, var: dict, msg: mqtt.MQTTMes
var["device"+index] = (dev.Device if hasattr(dev, "Device") else dev.create_device)(config)
# Durch das erneute Subscribe werden die Komponenten mit dem aktualisierten TCP-Client angelegt.
client.subscribe(f"openWB/system/device/{index}/component/+/config", 2)
client.subscribe(f"openWB/system/device/{index}/error_timestamp", 2)
elif re.search("^.+/device/[0-9]+/component/[0-9]+/simulation$", msg.topic) is not None:
index = get_index(msg.topic)
index_second = get_second_index(msg.topic)
var["device"+index].components["component"+index_second].sim_counter.data = dataclass_from_dict(
SimCounterState,
decode_payload(msg.payload))
elif re.search("^.+/device/[0-9]+/error_timestamp$", msg.topic) is not None:
index = get_index(msg.topic)
var["device"+index].client_error_context.error_timestamp = decode_payload(msg.payload)
elif re.search("^.+/device/[0-9]+/component/[0-9]+/config$", msg.topic) is not None:
index = get_index(msg.topic)
index_second = get_second_index(msg.topic)
Expand Down
Original file line number Diff line number Diff line change
@@ -1,10 +1,12 @@
#!/usr/bin/python3
import logging
from pathlib import Path
import time
from typing import Optional

from control import data
from helpermodules.utils.error_handling import CP_ERROR, ErrorTimerContext
from helpermodules.utils.run_command import run_command
from modules.chargepoints.openwb_series2_satellit.config import OpenWBseries2Satellit
from modules.common import modbus
from modules.common.abstract_chargepoint import AbstractChargepoint
Expand Down Expand Up @@ -74,34 +76,36 @@ def _validate_version(self):
def get_values(self) -> None:
with SingleComponentUpdateContext(self.fault_state):
if self.version is not None:
with self.client_error_context:
try:
self.delay_second_cp(self.CP1_DELAY)
with self._client.client:
self._client.check_hardware(self.fault_state)
if self.version is False:
self._validate_version()
currents = self._client.meter_client.get_currents()
phases_in_use = sum(1 for current in currents if current > 3)
plug_state, charge_state, _ = self._client.evse_client.get_plug_charge_state()

chargepoint_state = ChargepointState(
power=self._client.meter_client.get_power()[1],
currents=currents,
imported=self._client.meter_client.get_imported(),
exported=0,
voltages=self._client.meter_client.get_voltages(),
plug_state=plug_state,
charge_state=charge_state,
phases_in_use=phases_in_use,
serial_number=self._client.meter_client.get_serial_number(),
max_evse_current=self.max_evse_current
)
try:
self.delay_second_cp(self.CP1_DELAY)
with self._client.client, self.client_error_context:
self._client.check_hardware(self.fault_state)
if self.version is False:
self._validate_version()
currents = self._client.meter_client.get_currents()
phases_in_use = sum(1 for current in currents if current > 3)
plug_state, charge_state, _ = self._client.evse_client.get_plug_charge_state()
chargepoint_state = ChargepointState(
power=self._client.meter_client.get_power()[1],
currents=currents,
imported=self._client.meter_client.get_imported(),
exported=0,
voltages=self._client.meter_client.get_voltages(),
plug_state=plug_state,
charge_state=charge_state,
phases_in_use=phases_in_use,
serial_number=self._client.meter_client.get_serial_number(),
max_evse_current=self.max_evse_current
)
self.store.set(chargepoint_state)
self.client_error_context.reset_error_counter()
except AttributeError:
self._create_client()
self._validate_version()
except Exception:
if self.client_error_context.error_counter_exceeded():
run_command(f"{Path(__file__).resolve().parents[3]}/modules/chargepoints/"
"openwb_series2_satellit/restart_protoss_satellite")
except AttributeError:
self._create_client()
self._validate_version()
else:
self._create_client()
self._validate_version()
Expand Down
Binary file not shown.
8 changes: 2 additions & 6 deletions packages/modules/common/component_context.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
import logging
from threading import local
from typing import Callable, Optional, List, Union, Any, Dict
from typing import Optional, List, Union, Any, Dict
from helpermodules.constants import NO_ERROR

from modules.common.fault_state import ComponentInfo, FaultState, FaultStateLevel
Expand All @@ -19,13 +19,11 @@ class SingleComponentUpdateContext:

def __init__(self,
fault_state: FaultState,
error_handler: Callable = None,
update_always: bool = True,
reraise: bool = False):
self.__fault_state = fault_state
self.update_always = update_always
self.reraise = reraise
self.error_handler = error_handler

def __enter__(self):
log.debug("Update Komponente ['"+self.__fault_state.component_info.name+"']")
Expand All @@ -35,9 +33,7 @@ def __enter__(self):

def __exit__(self, exception_type, exception, exception_traceback) -> bool:
MultiComponentUpdateContext.override_subcomponent_state(self.__fault_state, exception, self.update_always)
if isinstance(exception, Exception) and self.error_handler is not None:
self.error_handler()
if self.reraise is False:
if self.reraise is False or exception is None:
return True
else:
return False
Expand Down
36 changes: 25 additions & 11 deletions packages/modules/common/configurable_device.py
Original file line number Diff line number Diff line change
Expand Up @@ -3,6 +3,8 @@
from typing import TypeVar, Generic, Dict, Any, Callable, Iterable, List

from dataclass_utils import dataclass_from_dict
from helpermodules import timecheck
from helpermodules.pub import Pub
from modules.common.abstract_device import AbstractDevice
from modules.common.component_context import SingleComponentUpdateContext, MultiComponentUpdateContext
from modules.common.fault_state import ComponentInfo, FaultState
Expand All @@ -22,9 +24,16 @@ def __init__(self, updater: Callable[[T_COMPONENT], None]):
self.__updater = updater

def __call__(self, components: Iterable[T_COMPONENT], error_handler: Callable) -> None:
# error_handler nur einmal ausführen, da er für das ganze Gerät gilt
run_error_handler = False
for component in components:
with SingleComponentUpdateContext(component.fault_state, error_handler):
self.__updater(component)
try:
with SingleComponentUpdateContext(component.fault_state, reraise=True):
self.__updater(component)
except Exception:
run_error_handler = True
if run_error_handler:
error_handler()


class MultiComponentUpdater:
Expand Down Expand Up @@ -66,27 +75,32 @@ def __init__(self,
device_config: T_DEVICE_CONFIG,
component_factory: ComponentFactory[Any, T_COMPONENT],
component_updater: ComponentUpdater[T_COMPONENT],
initializer: Callable = lambda: None) -> None:
initializer: Callable = lambda: None,
error_handler: Callable = lambda: None) -> None:
self.__initializer = initializer
self.__error_handler = error_handler
self.__component_factory = component_factory
self.__component_updater = component_updater
self.device_config = device_config
self.components: Dict[str, T_COMPONENT] = {}

self.error_timestamp = None
try:
self.__initializer()
except Exception:
log.exception(f"Initialisierung von Gerät {self.device_config.name} fehlgeschlagen")

def error_handler(self):
pass
# self.__initializer()
# for component in self.components.values():
# component.initialize()
def error_handler(self) -> None:
if self.error_timestamp is None:
self.error_timestamp = timecheck.create_timestamp()
Pub().pub(f"openWB/set/system/device/{self.device_config.id}/error_timestamp", self.error_timestamp)
log.debug(
f"Fehler bei Gerät {self.device_config.name} aufgetreten, Fehlerzeitstempel: {self.error_timestamp}")
if timecheck.check_timestamp(self.error_timestamp, 60) is False:
self.__error_handler()
self.error_timestamp = None
Pub().pub(self.topic, self.error_timestamp)

def add_component(self, component_config: T_COMPONENT_CONFIG) -> None:
# with SingleComponentUpdateContext(FaultState(ComponentInfo.from_component_config(component_config)),
# self.__initializer):
with SingleComponentUpdateContext(FaultState(ComponentInfo.from_component_config(component_config))):
component = self.__component_factory(component_config)
component.initialized = False
Expand Down
Binary file added packages/modules/common/restart_protoss_admin
Binary file not shown.
6 changes: 6 additions & 0 deletions packages/modules/devices/alpha_ess/alpha_ess/device.py
Original file line number Diff line number Diff line change
@@ -1,7 +1,9 @@
#!/usr/bin/env python3
import logging
from pathlib import Path
from typing import Iterable, Union

from helpermodules.utils.run_command import run_command
from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
from modules.devices.alpha_ess.alpha_ess.config import (
AlphaEss, AlphaEssBatSetup, AlphaEssCounterSetup, AlphaEssInverterSetup)
Expand Down Expand Up @@ -56,9 +58,13 @@ def initializer():
client = modbus.ModbusTcpClient_(
device_config.configuration.ip_address, device_config.configuration.port)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
bat=create_bat_component,
counter=create_counter_component,
Expand Down
6 changes: 6 additions & 0 deletions packages/modules/devices/growatt/growatt/device.py
Original file line number Diff line number Diff line change
@@ -1,7 +1,9 @@
#!/usr/bin/env python3
import logging
from pathlib import Path
from typing import Iterable, Union

from helpermodules.utils.run_command import run_command
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ConfigurableDevice, ComponentFactoryByType, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
Expand Down Expand Up @@ -48,9 +50,13 @@ def initializer():
nonlocal client
client = ModbusTcpClient_(device_config.configuration.ip_address, device_config.configuration.port)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
bat=create_bat_component,
counter=create_counter_component,
Expand Down
6 changes: 6 additions & 0 deletions packages/modules/devices/huawei/huawei/device.py
Original file line number Diff line number Diff line change
@@ -1,7 +1,9 @@
#!/usr/bin/env python3
import logging
from pathlib import Path
from typing import Iterable, Union

from helpermodules.utils.run_command import run_command
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
Expand Down Expand Up @@ -58,9 +60,13 @@ def initializer():
client = ModbusTcpClient_(device_config.configuration.ip_address,
device_config.configuration.port)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
bat=create_bat_component,
counter=create_counter_component,
Expand Down
6 changes: 6 additions & 0 deletions packages/modules/devices/openwb/openwb_bat_kit/device.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,8 @@
import logging
from pathlib import Path
from typing import Iterable

from helpermodules.utils.run_command import run_command
from modules.common import modbus
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
Expand All @@ -27,9 +29,13 @@ def initializer():
nonlocal client
client = modbus.ModbusTcpClient_("192.168.193.19", 8899)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
bat=create_bat_component,
),
Expand Down
6 changes: 6 additions & 0 deletions packages/modules/devices/openwb/openwb_evu_kit/device.py
Original file line number Diff line number Diff line change
@@ -1,7 +1,9 @@
import logging
from pathlib import Path
import time
from typing import Iterable, Union

from helpermodules.utils.run_command import run_command
from modules.common import modbus
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
Expand Down Expand Up @@ -40,9 +42,13 @@ def initializer():
nonlocal client
client = modbus.ModbusTcpClient_("192.168.193.15", 8899)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
bat=create_bat_component,
counter=create_counter_component,
Expand Down
6 changes: 6 additions & 0 deletions packages/modules/devices/openwb/openwb_flex/device.py
Original file line number Diff line number Diff line change
@@ -1,7 +1,9 @@
#!/usr/bin/env python3
import logging
from pathlib import Path
from typing import Iterable, Union

from helpermodules.utils.run_command import run_command
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ConfigurableDevice, ComponentFactoryByType, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
Expand Down Expand Up @@ -46,9 +48,13 @@ def initializer():
nonlocal client
client = ModbusTcpClient_(device_config.configuration.ip_address, device_config.configuration.port)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
bat=create_bat_component,
consumption_counter=create_consumption_counter_component,
Expand Down
6 changes: 6 additions & 0 deletions packages/modules/devices/openwb/openwb_pv_kit/device.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,8 @@
import logging
from pathlib import Path
from typing import Iterable

from helpermodules.utils.run_command import run_command
from modules.common import modbus
from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
Expand All @@ -27,9 +29,13 @@ def initializer():
nonlocal client
client = modbus.ModbusTcpClient_("192.168.193.13", 8899)

def error_handler():
run_command(f"{Path(__file__).resolve().parents[4]}/modules/common/restart_protoss_admin")

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
error_handler=error_handler,
component_factory=ComponentFactoryByType(
inverter=create_inverter_component,
),
Expand Down