46 changes: 46 additions & 0 deletions packages/modules/devices/siemens/siemens_logo84/bat.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,46 @@
#!/usr/bin/env python3
from typing import TypedDict, Any

from modules.common import modbus
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType
from modules.common.store import get_bat_value_store
from modules.devices.siemens.siemens_logo84.config import SiemensLogo84BatSetup


class KwargsDict(TypedDict):
client: modbus.ModbusTcpClient_
modbus_id: int


class SiemensLogo84Bat(AbstractBat):
def __init__(self, component_config: SiemensLogo84BatSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__tcp_client: modbus.ModbusTcpClient_ = self.kwargs['client']
self.__modbus_id: int = self.kwargs['modbus_id']
self.store = get_bat_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

def update(self) -> None:
with self.__tcp_client:
power = self.__tcp_client.read_holding_registers(342, ModbusDataType.INT_16, unit=self.__modbus_id) * -1
soc = self.__tcp_client.read_holding_registers(343, ModbusDataType.INT_16, unit=self.__modbus_id)
imported = self.__tcp_client.read_holding_registers(344, ModbusDataType.INT_16, unit=self.__modbus_id)*1000
exported = self.__tcp_client.read_holding_registers(345, ModbusDataType.INT_16, unit=self.__modbus_id)*1000

bat_state = BatState(
power=power,
soc=soc,
imported=imported,
exported=exported
)
self.store.set(bat_state)


component_descriptor = ComponentDescriptor(configuration_factory=SiemensLogo84BatSetup)
38 changes: 38 additions & 0 deletions packages/modules/devices/siemens/siemens_logo84/config.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,38 @@
from typing import Optional

from modules.common.component_setup import ComponentSetup
from ..vendor import vendor_descriptor


class SiemensLogo84Configuration:
def __init__(self, modbus_id: int = 1, ip_address: Optional[str] = None, port: int = 507):
self.modbus_id = modbus_id
self.ip_address = ip_address
self.port = port


class SiemensLogo84:
def __init__(self,
name: str = "Siemens LOGO!8.4",
type: str = "siemens_logo84",
id: int = 0,
configuration: SiemensLogo84Configuration = None) -> None:
self.name = name
self.type = type
self.vendor = vendor_descriptor.configuration_factory().type
self.id = id
self.configuration = configuration or SiemensLogo84Configuration()


class SiemensLogo84BatConfiguration:
def __init__(self):
pass


class SiemensLogo84BatSetup(ComponentSetup[SiemensLogo84BatConfiguration]):
def __init__(self,
name: str = "Siemens LOGO! 8.4 Speicher-Zähler",
type: str = "bat",
id: int = 0,
configuration: SiemensLogo84BatConfiguration = None) -> None:
super().__init__(name, type, id, configuration or SiemensLogo84BatConfiguration())
41 changes: 41 additions & 0 deletions packages/modules/devices/siemens/siemens_logo84/device.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,41 @@
#!/usr/bin/env python3
import logging
from typing import Iterable, Union

from modules.common.abstract_device import DeviceDescriptor
from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
from modules.devices.siemens.siemens_logo84.config import (SiemensLogo84, SiemensLogo84BatSetup)
from modules.devices.siemens.siemens_logo84 import bat

log = logging.getLogger(__name__)


def create_device(device_config: SiemensLogo84):
client = None

def create_bat_component(component_config: SiemensLogo84BatSetup):
nonlocal client
return bat.SiemensLogo84Bat(component_config, client=client, modbus_id=device_config.configuration.modbus_id)

def update_components(components: Iterable[Union[bat.SiemensLogo84Bat]]):
nonlocal client
with client:
for component in components:
component.update()

def initializer():
nonlocal client
client = ModbusTcpClient_(device_config.configuration.ip_address, device_config.configuration.port)

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
component_factory=ComponentFactoryByType(
bat=create_bat_component
),
component_updater=MultiComponentUpdater(update_components)
)


device_descriptor = DeviceDescriptor(configuration_factory=SiemensLogo84)