14 changes: 10 additions & 4 deletions packages/control/bat_all.py
Original file line number Diff line number Diff line change
Expand Up @@ -286,25 +286,31 @@ def set_power_limit_controllable(self):
self.data.get.power_limit_controllable = False

def get_power_limit(self):
chargepoint_by_chagemodes = get_chargepoints_by_chargemodes(CONSIDERED_CHARGE_MODES_ADDITIONAL_CURRENT)
power_of_chargepoints_by_chagemodes = sum(
[cp.data.get.power for cp in chargepoint_by_chagemodes if cp.data.get.power is not None])
if (self.data.config.power_limit_mode != BatPowerLimitMode.NO_LIMIT.value
and len(get_chargepoints_by_chargemodes(CONSIDERED_CHARGE_MODES_ADDITIONAL_CURRENT)) > 0 and
and len(chargepoint_by_chagemodes) > 0 and
power_of_chargepoints_by_chagemodes > 0 and
self.data.get.power_limit_controllable and
# Nur wenn kein Überschuss im System ist, Speicherleistung begrenzen.
self.data.get.power <= 0 and
data.data.counter_all_data.get_evu_counter().data.get.power >= 0):
data.data.counter_all_data.get_evu_counter().data.get.power >= -100):
if self.data.config.power_limit_mode == BatPowerLimitMode.LIMIT_STOP.value:
self.data.set.power_limit = 0
elif self.data.config.power_limit_mode == BatPowerLimitMode.LIMIT_TO_HOME_CONSUMPTION.value:
self.data.set.power_limit = data.data.counter_all_data.data.set.home_consumption
self.data.set.power_limit = data.data.counter_all_data.data.set.home_consumption * -1
log.debug(f"Speicher-Leistung begrenzen auf {self.data.set.power_limit/1000}kW")
else:
self.data.set.power_limit = None
control_range_low = data.data.general_data.data.chargemode_config.pv_charging.control_range[0]
control_range_high = data.data.general_data.data.chargemode_config.pv_charging.control_range[1]
control_range_center = control_range_high - (control_range_high - control_range_low) / 2
if len(get_chargepoints_by_chargemodes(CONSIDERED_CHARGE_MODES_ADDITIONAL_CURRENT)) == 0:
if len(chargepoint_by_chagemodes) == 0:
log.debug("Speicher-Leistung nicht begrenzen, "
"da keine Ladepunkte in einem Lademodus mit Netzbezug sind.")
elif power_of_chargepoints_by_chagemodes <= 0:
log.debug("Speicher-Leistung nicht begrenzen, da kein Ladepunkt mit Netzubezug lädt.")
elif self.data.get.power_limit_controllable is False:
log.debug("Speicher-Leistung nicht begrenzen, da keine regelbaren Speicher vorhanden sind.")
elif self.data.get.power > 0:
Expand Down
8 changes: 5 additions & 3 deletions packages/control/bat_all_test.py
Original file line number Diff line number Diff line change
Expand Up @@ -154,7 +154,9 @@ def test_get_charging_power_left(params: Params, caplog, data_fixture, monkeypat


def default_chargepoint_factory() -> List[Chargepoint]:
return [Chargepoint(3, None)]
cp = Chargepoint(3, None)
cp.data.get.power = 1400
return [cp]


@dataclass
Expand All @@ -176,10 +178,10 @@ class PowerLimitParams:
power_limit_mode=BatPowerLimitMode.LIMIT_STOP.value),
PowerLimitParams("Begrenzung immer, Speicher lädt", None, bat_power=100,
power_limit_mode=BatPowerLimitMode.LIMIT_STOP.value),
PowerLimitParams("Begrenzung immer,Einspeisung", None, evu_power=-100,
PowerLimitParams("Begrenzung immer,Einspeisung", None, evu_power=-110,
power_limit_mode=BatPowerLimitMode.LIMIT_STOP.value),
PowerLimitParams("Begrenzung immer", 0, power_limit_mode=BatPowerLimitMode.LIMIT_STOP.value),
PowerLimitParams("Begrenzung Hausverbrauch", 456,
PowerLimitParams("Begrenzung Hausverbrauch", -456,
power_limit_mode=BatPowerLimitMode.LIMIT_TO_HOME_CONSUMPTION.value),
]

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -114,7 +114,7 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
log.debug("Aktive Batteriesteuerung vorhanden. Setze externe Steuerung.")
values_to_write = {
"Externe_Steuerung": 802,
"Wirkleistungsvorgabe": power_limit
"Wirkleistungsvorgabe": abs(power_limit)
}
self._write_registers(values_to_write, unit)
self.last_mode = 'limited'
Expand Down
3 changes: 2 additions & 1 deletion packages/modules/devices/sungrow/sungrow/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -94,7 +94,8 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
self.__tcp_client.write_registers(13050, [0xBB], data_type=ModbusDataType.UINT_16, unit=unit)
self.last_mode = 'discharge'
# Die maximale Entladeleistung begrenzen auf 5000W, maximaler Wertebereich Modbusregister.
power_value = int(min(power_limit, 5000))
power_value = int(min(abs(power_limit), 5000))
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W entladen für den Hausverbrauch")
self.__tcp_client.write_registers(13051, [power_value], data_type=ModbusDataType.UINT_16, unit=unit)

def power_limit_controllable(self) -> bool:
Expand Down
2 changes: 1 addition & 1 deletion packages/modules/devices/victron/victron/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -78,7 +78,7 @@ def set_power_limit(self, power_limit: Optional[int]) -> None:
self.__tcp_client.write_registers(39, [0], data_type=ModbusDataType.UINT_16, unit=228)
self.last_mode = 'discharge'
# Die maximale Entladeleistung begrenzen auf 5000W
power_value = int(min(power_limit, 5000)) * -1
power_value = int(min(power_limit, 5000))
log.debug(f"Aktive Batteriesteuerung. Batterie wird mit {power_value} W entladen")
self.__tcp_client.write_registers(37, [power_value & 0xFFFF], data_type=ModbusDataType.INT_16, unit=228)

Expand Down