Original file line number Diff line number Diff line change
Expand Up @@ -337,28 +337,30 @@ def check_deviating_contactor_states(self, phase_a: int, phase_b: int) -> bool:

def _is_phase_switch_required(self) -> bool:
phase_switch_required = False
if self.data.control_parameter.state == ChargepointState.WAIT_FOR_USING_PHASES:
phase_switch_required = False
# Manche EVs brauchen nach der Umschaltung mehrere Zyklen, bis sie mit den drei Phasen laden. Dann darf
# nicht zwischendurch eine neue Umschaltung getriggert werden.
if ((((self.data.control_parameter.state == ChargepointState.PHASE_SWITCH_AWAITED or
elif ((((self.data.control_parameter.state == ChargepointState.PHASE_SWITCH_AWAITED or
self.data.control_parameter.state == ChargepointState.SWITCH_OFF_DELAY) and
# Nach Ablauf der Laden aktiv halten Zeit, sollte mit der vorgegebenen Phasenzahl geladen werden.
self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use)) or
self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use)) or
# Vorgegebene Phasenzahl hat sich geändert und es wird geladen
(self.check_deviating_contactor_states(self.data.set.phases_to_use,
self.data.control_parameter.phases) and
(self.check_deviating_contactor_states(self.data.set.phases_to_use,
self.data.control_parameter.phases) and
self.data.control_parameter.state in CHARGING_STATES)) and
# Wenn ein Soll-Strom vorgegeben ist, muss das Auto auch laden, damit umgeschaltet wird, sonst
# wird zB bei automatischer Umschaltung ständig versucht auf 1 Phase zurück zu schalten, wenn
# das Auto bei 3 Phasen voll ist.
((self.data.set.current != 0 and self.data.get.charge_state) or
(self.data.set.current != 0 and self.data.set.current_prev == 0) or
self.data.set.current == 0)):
((self.data.set.current != 0 and self.data.get.charge_state) or
(self.data.set.current != 0 and self.data.set.current_prev == 0) or
self.data.set.current == 0)):
phase_switch_required = True
if (self.data.control_parameter.state == ChargepointState.NO_CHARGING_ALLOWED and
(self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use) or
elif (self.data.control_parameter.state == ChargepointState.NO_CHARGING_ALLOWED and
(self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use) or
# Vorgegebene Phasenzahl hat sich geändert
self.check_deviating_contactor_states(self.data.set.phases_to_use,
self.data.control_parameter.phases)) and
self.check_deviating_contactor_states(self.data.set.phases_to_use,
self.data.control_parameter.phases)) and
# Wenn der Ladevorgang gestartet wird, muss vor dem ersten Laden umgeschaltet werden.
self.data.set.current != 0):
phase_switch_required = True
Expand Down