51 changes: 51 additions & 0 deletions packages/modules/devices/algodue/algodue/bat.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
#!/usr/bin/env python3
from typing import Any, TypedDict

from modules.devices.algodue.algodue.config import AlgodueBatSetup
from modules.common import modbus
from modules.common.abstract_device import AbstractBat
from modules.common.component_state import BatState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType
from modules.common.simcount import SimCounter
from modules.common.store import get_bat_value_store


class KwargsDict(TypedDict):
device_id: int
tcp_client: modbus.ModbusTcpClient_
modbus_id: int


class AlgodueBat(AbstractBat):
def __init__(self, component_config: AlgodueBatSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__device_id: int = self.kwargs['device_id']
self.__tcp_client: modbus.ModbusTcpClient_ = self.kwargs['tcp_client']
self.__modbus_id: int = self.kwargs['modbus_id']
self.sim_counter = SimCounter(self.__device_id, self.component_config.id, prefix="speicher")
self.store = get_bat_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

def update(self):
currents = self.__tcp_client.read_input_registers(
0x100E, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
powers = self.__tcp_client.read_input_registers(0x1020, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power = sum(powers)

imported, exported = self.sim_counter.sim_count(power)

bat_state = BatState(
power=power,
currents=currents,
imported=imported,
exported=exported
)
self.store.set(bat_state)


component_descriptor = ComponentDescriptor(configuration_factory=AlgodueBatSetup)
35 changes: 35 additions & 0 deletions packages/modules/devices/algodue/algodue/config.py
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,7 @@

from modules.common.component_setup import ComponentSetup
from ..vendor import vendor_descriptor
from helpermodules.auto_str import auto_str


class AlgodueConfiguration:
Expand All @@ -24,15 +25,49 @@ def __init__(self,
self.configuration = configuration or AlgodueConfiguration()


@auto_str
class AlgodueCounterConfiguration:
def __init__(self):
pass


@auto_str
class AlgodueCounterSetup(ComponentSetup[AlgodueCounterConfiguration]):
def __init__(self,
name: str = "Algodue Zähler",
type: str = "counter",
id: int = 0,
configuration: AlgodueCounterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or AlgodueCounterConfiguration())


@auto_str
class AlgodueInverterConfiguration:
def __init__(self):
pass


@auto_str
class AlgodueInverterSetup(ComponentSetup[AlgodueInverterConfiguration]):
def __init__(self,
name: str = "Algodue Wechselrichterzähler",
type: str = "inverter",
id: int = 0,
configuration: AlgodueInverterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or AlgodueInverterConfiguration())


@auto_str
class AlgodueBatConfiguration:
def __init__(self):
pass


@auto_str
class AlgodueBatSetup(ComponentSetup[AlgodueBatConfiguration]):
def __init__(self,
name: str = "Algodue Speicherzähler",
type: str = "bat",
id: int = 0,
configuration: AlgodueBatConfiguration = None) -> None:
super().__init__(name, type, id, configuration or AlgodueBatConfiguration())
20 changes: 9 additions & 11 deletions packages/modules/devices/algodue/algodue/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -32,17 +32,15 @@ def initialize(self) -> None:
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

def update(self):
with self.__tcp_client:

frequency = self.__tcp_client.read_input_registers(0x1038, ModbusDataType.FLOAT_32, unit=self.__modbus_id)
currents = self.__tcp_client.read_input_registers(
0x100E, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
powers = self.__tcp_client.read_input_registers(0x1020, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power = sum(powers)
voltages = self.__tcp_client.read_input_registers(
0x1000, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power_factors = self.__tcp_client.read_input_registers(
0x1018, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
frequency = self.__tcp_client.read_input_registers(0x1038, ModbusDataType.FLOAT_32, unit=self.__modbus_id)
currents = self.__tcp_client.read_input_registers(
0x100E, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
powers = self.__tcp_client.read_input_registers(0x1020, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power = sum(powers)
voltages = self.__tcp_client.read_input_registers(
0x1000, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power_factors = self.__tcp_client.read_input_registers(
0x1018, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)

imported, exported = self.sim_counter.sim_count(power)

Expand Down
19 changes: 15 additions & 4 deletions packages/modules/devices/algodue/algodue/device.py
Original file line number Diff line number Diff line change
@@ -1,10 +1,10 @@
#!/usr/bin/env python3
import logging
from typing import Iterable
from typing import Iterable, Union

from modules.common.configurable_device import ComponentFactoryByType, ConfigurableDevice, MultiComponentUpdater
from modules.devices.algodue.algodue import counter
from modules.devices.algodue.algodue.config import Algodue, AlgodueCounterSetup
from modules.devices.algodue.algodue import counter, inverter, bat
from modules.devices.algodue.algodue.config import Algodue, AlgodueCounterSetup, AlgodueInverterSetup, AlgodueBatSetup
from modules.common import modbus
from modules.common.abstract_device import DeviceDescriptor
from modules.common.component_context import SingleComponentUpdateContext
Expand All @@ -20,7 +20,18 @@ def create_counter_component(component_config: AlgodueCounterSetup):
return counter.AlgodueCounter(component_config=component_config, device_id=device_config.id,
tcp_client=client, modbus_id=device_config.configuration.modbus_id)

def update_components(components: Iterable[counter.AlgodueCounter]):
def create_inverter_component(component_config: AlgodueInverterSetup):
nonlocal client
return inverter.AlgodueInverter(component_config=component_config, device_id=device_config.id,
tcp_client=client, modbus_id=device_config.configuration.modbus_id)

def create_bat_component(component_config: AlgodueBatSetup):
nonlocal client
return bat.AlgodueBat(component_config=component_config, device_id=device_config.id,
tcp_client=client, modbus_id=device_config.configuration.modbus_id)

def update_components(
components: Iterable[Union[counter.AlgodueCounter, inverter.AlgodueInverter, bat.AlgodueBat]]):
with client:
for component in components:
with SingleComponentUpdateContext(component.fault_state):
Expand Down
50 changes: 50 additions & 0 deletions packages/modules/devices/algodue/algodue/inverter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,50 @@
#!/usr/bin/env python3
from typing import Any, TypedDict

from modules.devices.algodue.algodue.config import AlgodueInverterSetup
from modules.common import modbus
from modules.common.abstract_device import AbstractInverter
from modules.common.component_state import InverterState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType
from modules.common.simcount import SimCounter
from modules.common.store import get_inverter_value_store


class KwargsDict(TypedDict):
device_id: int
tcp_client: modbus.ModbusTcpClient_
modbus_id: int


class AlgodueInverter(AbstractInverter):
def __init__(self, component_config: AlgodueInverterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__device_id: int = self.kwargs['device_id']
self.__tcp_client: modbus.ModbusTcpClient_ = self.kwargs['tcp_client']
self.__modbus_id: int = self.kwargs['modbus_id']
self.sim_counter = SimCounter(self.__device_id, self.component_config.id, prefix="pv")
self.store = get_inverter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

def update(self):
currents = self.__tcp_client.read_input_registers(
0x100E, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
powers = self.__tcp_client.read_input_registers(0x1020, [ModbusDataType.FLOAT_32]*3, unit=self.__modbus_id)
power = sum(powers)

_, exported = self.sim_counter.sim_count(power)

inverter_state = InverterState(
power=power,
currents=currents,
exported=exported
)
self.store.set(inverter_state)


component_descriptor = ComponentDescriptor(configuration_factory=AlgodueInverterSetup)