Skip to content
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
62 changes: 39 additions & 23 deletions packages/modules/devices/sungrow/sungrow/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -33,39 +33,55 @@ def initialize(self) -> None:
self.store = get_bat_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.last_mode = 'Undefined'
self.firmware_check = self.check_firmware_register()

def check_firmware_register(self) -> bool:
if Firmware(self.device_config.configuration.firmware) == Firmware.v1:
return False
unit = self.device_config.configuration.modbus_id
try:
self.__tcp_client.read_input_registers(5213, ModbusDataType.INT_32,
wordorder=Endian.Little, unit=unit)
log.debug("Wechselrichter Firmware ist größer gleich 95.09")
return True
except Exception:
log.debug("Wechselrichter Firmware ist kleiner als 95.09")
return False

def update(self) -> None:
unit = self.device_config.configuration.modbus_id
soc = int(
self.__tcp_client.read_input_registers(13022, ModbusDataType.UINT_16, unit=unit) / 10)
# Es gibt nur einen DC Strom der Batterie, daher Aufteilen auf 3 Phasenströme
bat_current = self.__tcp_client.read_input_registers(13020, ModbusDataType.INT_16, unit=unit) * -0.1
currents = [bat_current / 3] * 3

if (
Firmware(self.device_config.configuration.firmware) == Firmware.v2
and self.device_config.configuration.version == Version.SH
):
bat_power = self.__tcp_client.read_input_registers(13021, ModbusDataType.INT_16, unit=unit) * -1
else:
soc = int(self.__tcp_client.read_input_registers(13022, ModbusDataType.UINT_16, unit=unit) / 10)
version = Version(self.device_config.configuration.version)

if Firmware(self.device_config.configuration.firmware) == Firmware.v2:
if self.firmware_check: # Firmware >= 95.09
bat_current = self.__tcp_client.read_input_registers(5630, ModbusDataType.INT_16, unit=unit) * -0.1
bat_power = self.__tcp_client.read_input_registers(5213, ModbusDataType.INT_32,
wordorder=Endian.Little, unit=unit) * -1
else: # Firmware between 95.03 and 95.09
bat_current = self.__tcp_client.read_input_registers(13020, ModbusDataType.INT_16, unit=unit) * -0.1
if version == Version.SH:
bat_power = self.__tcp_client.read_input_registers(13021, ModbusDataType.INT_16, unit=unit)
elif version == Version.SH_winet_dongle:
bat_power = self.__tcp_client.read_input_registers(13021, ModbusDataType.UINT_16, unit=unit)
total_power = self.__tcp_client.read_input_registers(13033, ModbusDataType.INT_32,
wordorder=Endian.Little, unit=unit)
pv_power = self.__tcp_client.read_input_registers(5016, ModbusDataType.UINT_32,
wordorder=Endian.Little, unit=unit)
if total_power > pv_power:
bat_power = bat_power * -1
else: # Firmware.v1 (Firmware < 95.03)
bat_current = self.__tcp_client.read_input_registers(13020, ModbusDataType.INT_16, unit=unit) * -0.1
bat_power = self.__tcp_client.read_input_registers(13021, ModbusDataType.UINT_16, unit=unit)

# Beim WiNet S-Dongle fehlt das Register für das Vorzeichen der Speicherleistung
if self.device_config.configuration.version == Version.SH_winet_dongle:
total_power = self.__tcp_client.read_input_registers(13033, ModbusDataType.INT_32,
wordorder=Endian.Little, unit=unit)
pv_power = self.__tcp_client.read_input_registers(5016, ModbusDataType.UINT_32,
wordorder=Endian.Little, unit=unit)

# Ist die Gesamtleistung des WR größer als die PV-Erzeugung wird der Speicher entladen
if total_power > pv_power:
bat_power = bat_power * -1
else:
if version in (Version.SH, Version.SH_winet_dongle):
resp = self.__tcp_client._delegate.read_input_registers(13000, 1, unit=unit)
binary = bin(resp.registers[0])[2:].zfill(8)
if binary[5] == "1":
bat_power = bat_power * -1

currents = [bat_current / 3] * 3

imported, exported = self.sim_counter.sim_count(bat_power)
bat_state = BatState(
power=bat_power,
Expand Down