38 changes: 38 additions & 0 deletions packages/modules/devices/azzurro_zcs/azzurro_zcs_3p/config.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,38 @@
from typing import Optional

from modules.common.component_setup import ComponentSetup
from ..vendor import vendor_descriptor


class ZCS3PConfiguration:
def __init__(self, modbus_id: int = 1, ip_address: Optional[str] = None, port: int = 502):
self.modbus_id = modbus_id
self.ip_address = ip_address
self.port = port


class ZCS3P:
def __init__(self,
name: str = "Azzurro - ZCS 3PH 12KTL",
type: str = "azzurro_zcs_3p",
id: int = 0,
configuration: ZCS3PConfiguration = None) -> None:
self.name = name
self.type = type
self.vendor = vendor_descriptor.configuration_factory().type
self.id = id
self.configuration = configuration or ZCS3PConfiguration()


class ZCSPvInverterConfiguration:
def __init__(self):
pass


class ZCSPvInverterSetup(ComponentSetup[ZCSPvInverterConfiguration]):
def __init__(self,
name: str = "ZCS Azzurro Wechselrichter",
type: str = "pv_inverter",
id: int = 0,
configuration: ZCSPvInverterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or ZCSPvInverterConfiguration())
45 changes: 45 additions & 0 deletions packages/modules/devices/azzurro_zcs/azzurro_zcs_3p/device.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,45 @@
#!/usr/bin/env python3
import logging
from typing import Iterable

from modules.common.abstract_device import DeviceDescriptor
from modules.common.component_context import SingleComponentUpdateContext
from modules.common.configurable_device import ConfigurableDevice, ComponentFactoryByType, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
from modules.devices.azzurro_zcs.azzurro_zcs_3p.config import ZCS3P, ZCSPvInverterSetup
from modules.devices.azzurro_zcs.azzurro_zcs_3p.pv_inverter import ZCSPvInverter

log = logging.getLogger(__name__)


def create_device(device_config: ZCS3P):
client = None

def create_pv_inverter_component(component_config: ZCSPvInverterSetup):
nonlocal client
return ZCSPvInverter(component_config=component_config,
modbus_id=device_config.configuration.modbus_id,
client=client)

def update_components(components: Iterable[ZCSPvInverter]):
nonlocal client
with client:
for component in components:
with SingleComponentUpdateContext(component.fault_state):
component.update()

def initializer():
nonlocal client
client = ModbusTcpClient_(device_config.configuration.ip_address, device_config.configuration.port)

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
component_factory=ComponentFactoryByType(
pv_inverter=create_pv_inverter_component,
),
component_updater=MultiComponentUpdater(update_components)
)


device_descriptor = DeviceDescriptor(configuration_factory=ZCS3P)
53 changes: 53 additions & 0 deletions packages/modules/devices/azzurro_zcs/azzurro_zcs_3p/pv_inverter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
#!/usr/bin/env python3
import logging
from typing import TypedDict, Any
from modules.common.abstract_device import AbstractInverter
from modules.common.component_state import InverterState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType, ModbusTcpClient_
from modules.common.store import get_inverter_value_store
from modules.devices.azzurro_zcs.azzurro_zcs_3p.config import ZCSPvInverterSetup

log = logging.getLogger(__name__)


class KwargsDict(TypedDict):
client: ModbusTcpClient_
modbus_id: int


class ZCSPvInverter(AbstractInverter):
def __init__(self, component_config: ZCSPvInverterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__modbus_id: int = self.kwargs['modbus_id']
self.client: ModbusTcpClient_ = self.kwargs['client']
self.store = get_inverter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

def update(self) -> None:
power = exported = 0
currents = None
try:
power = self.client.read_holding_registers(0x0485, ModbusDataType.INT_16, unit=self.__modbus_id)*10
exported = self.client.read_holding_registers(0x0684, ModbusDataType.UINT_32, unit=self.__modbus_id)*10
currents = [
self.client.read_holding_registers(0x48E, ModbusDataType.INT_16, unit=self.__modbus_id)*0.01,
self.client.read_holding_registers(0x499, ModbusDataType.INT_16, unit=self.__modbus_id)*0.01,
self.client.read_holding_registers(0x4A4, ModbusDataType.INT_16, unit=self.__modbus_id)*0.01
]
except Exception:
log.debug("Modbus could not be read.")

inverter_state = InverterState(
currents=currents,
power=power,
exported=exported
)
self.store.set(inverter_state)


component_descriptor = ComponentDescriptor(configuration_factory=ZCSPvInverterSetup)
Empty file.
Empty file.
42 changes: 42 additions & 0 deletions packages/modules/devices/chint/chint/config.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,42 @@
from typing import Optional
from helpermodules.auto_str import auto_str
from modules.common.component_setup import ComponentSetup

from ..vendor import vendor_descriptor


@auto_str
class CHINTConfiguration:
def __init__(self, ip_address: Optional[str] = None, port: int = 8899):
self.ip_address = ip_address
self.port = port


@auto_str
class CHINT:
def __init__(self,
name: str = "CHINT",
type: str = "chint",
id: int = 0,
configuration: CHINTConfiguration = None) -> None:
self.name = name
self.type = type
self.vendor = vendor_descriptor.configuration_factory().type
self.id = id
self.configuration = configuration or CHINTConfiguration()


@auto_str
class CHINTCounterConfiguration:
def __init__(self, modbus_id: int = 1):
self.modbus_id = modbus_id


@auto_str
class CHINTCounterSetup(ComponentSetup[CHINTCounterConfiguration]):
def __init__(self,
name: str = "CHINT DTSU666 Zähler",
type: str = "counter",
id: int = 0,
configuration: CHINTCounterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or CHINTCounterConfiguration())
71 changes: 71 additions & 0 deletions packages/modules/devices/chint/chint/counter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,71 @@
#!/usr/bin/env python3
import logging
from typing import TypedDict, Any
from modules.common.abstract_device import AbstractCounter
from modules.common.component_state import CounterState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType, ModbusTcpClient_
from modules.common.store import get_counter_value_store
from modules.devices.chint.chint.config import CHINTCounterSetup

log = logging.getLogger(__name__)


class KwargsDict(TypedDict):
client: ModbusTcpClient_


class CHINTCounter(AbstractCounter):
def __init__(self, component_config: CHINTCounterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.client: ModbusTcpClient_ = self.kwargs['client']
self.store = get_counter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.__modbus_id = self.component_config.configuration.modbus_id

def update(self):
powers = voltages = currents = power_factors = None
imported_ep = exported_ep = power = frequency = 0
irat = self.client.read_holding_registers(0x0006, ModbusDataType.INT_16, unit=self.__modbus_id)
urat = self.client.read_holding_registers(0x0007, ModbusDataType.INT_16, unit=self.__modbus_id)
power_ratio = urat*0.1*irat*0.1

frequency = self.client.read_holding_registers(0x2044, ModbusDataType.FLOAT_32, unit=self.__modbus_id)/100
power = self.client.read_holding_registers(0x2012,
ModbusDataType.FLOAT_32, unit=self.__modbus_id) * power_ratio
powers = [self.client.read_holding_registers(reg, ModbusDataType.FLOAT_32, unit=self.__modbus_id) * power_ratio
for reg in [0x2014, 0x2016, 0x2018]]
voltage_ratio = urat*0.1*0.1
voltages = [self.client.read_holding_registers(
reg, ModbusDataType.FLOAT_32, unit=self.__modbus_id) * voltage_ratio
for reg in [0x2006, 0x2008, 0x200A]]
current_ratio = irat*0.001
currents = [self.client.read_holding_registers(
reg, ModbusDataType.FLOAT_32, unit=self.__modbus_id) * current_ratio
for reg in [0x200C, 0x200E, 0x2010]]
power_factors = [self.client.read_holding_registers(reg, ModbusDataType.FLOAT_32, unit=self.__modbus_id) * 0.001
for reg in [0x202C, 0x202E, 0x2030]]
ep_ratio = irat * urat * 100
imported_ep = self.client.read_holding_registers(0x401E,
ModbusDataType.FLOAT_32, unit=self.__modbus_id) * ep_ratio
exported_ep = self.client.read_holding_registers(0x4028,
ModbusDataType.FLOAT_32, unit=self.__modbus_id) * ep_ratio

counter_state = CounterState(
currents=currents,
imported=imported_ep,
exported=exported_ep,
power=power,
frequency=frequency,
power_factors=power_factors,
powers=powers,
voltages=voltages
)
self.store.set(counter_state)


component_descriptor = ComponentDescriptor(configuration_factory=CHINTCounterSetup)
42 changes: 42 additions & 0 deletions packages/modules/devices/chint/chint/device.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,42 @@
#!/usr/bin/env python3
import logging
from typing import Iterable, Union

from modules.common.abstract_device import DeviceDescriptor
from modules.common.component_context import SingleComponentUpdateContext
from modules.common.configurable_device import ConfigurableDevice, ComponentFactoryByType, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
from modules.devices.chint.chint.config import CHINT, CHINTCounterSetup
from modules.devices.chint.chint.counter import CHINTCounter

log = logging.getLogger(__name__)


def create_device(device_config: CHINT):
client = None

def create_counter_component(component_config: CHINTCounterSetup):
nonlocal client
return CHINTCounter(component_config=component_config, client=client)

def update_components(components: Iterable[Union[CHINTCounter]]):
with client:
for component in components:
with SingleComponentUpdateContext(component.fault_state):
component.update()

def initializer():
nonlocal client
client = ModbusTcpClient_(device_config.configuration.ip_address, device_config.configuration.port)

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
component_factory=ComponentFactoryByType(
counter=create_counter_component,
),
component_updater=MultiComponentUpdater(update_components)
)


device_descriptor = DeviceDescriptor(configuration_factory=CHINT)
14 changes: 14 additions & 0 deletions packages/modules/devices/chint/vendor.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,14 @@
from pathlib import Path

from modules.common.abstract_device import DeviceDescriptor
from modules.devices.vendors import VendorGroup


class Vendor:
def __init__(self):
self.type = Path(__file__).parent.name
self.vendor = "CHINT"
self.group = VendorGroup.VENDORS.value


vendor_descriptor = DeviceDescriptor(configuration_factory=Vendor)