Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
58 changes: 58 additions & 0 deletions packages/modules/devices/kostal/kostal_piko_ci/config.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,58 @@
from typing import Optional

from helpermodules.auto_str import auto_str
from modules.common.component_setup import ComponentSetup
from ..vendor import vendor_descriptor


class KostalPikoCiConfiguration:
def __init__(self,
ip_address: Optional[str] = None,
port: int = 502):
self.ip_address = ip_address
self.port = port


class KostalPikoCi:
def __init__(self,
name: str = "Kostal Piko CI",
type: str = "kostal_piko_ci",
id: int = 0,
configuration: KostalPikoCiConfiguration = None) -> None:
self.name = name
self.type = type
self.vendor = vendor_descriptor.configuration_factory().type
self.id = id
self.configuration = configuration or KostalPikoCiConfiguration()


@auto_str
class KostalPikoCiCounterConfiguration:
def __init__(self, modbus_id: int = 75):
self.modbus_id = modbus_id


@auto_str
class KostalPikoCiCounterSetup(ComponentSetup[KostalPikoCiCounterConfiguration]):
def __init__(self,
name: str = "Kostal Piko CI Zähler",
type: str = "counter",
id: int = 0,
configuration: KostalPikoCiCounterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or KostalPikoCiCounterConfiguration())


@auto_str
class KostalPikoCiInverterConfiguration:
def __init__(self, modbus_id: int = 75):
self.modbus_id = modbus_id


@auto_str
class KostalPikoCiInverterSetup(ComponentSetup[KostalPikoCiInverterConfiguration]):
def __init__(self,
name: str = "Kostal Piko CI Wechselrichter",
type: str = "inverter",
id: int = 0,
configuration: KostalPikoCiInverterConfiguration = None) -> None:
super().__init__(name, type, id, configuration or KostalPikoCiInverterConfiguration())
50 changes: 50 additions & 0 deletions packages/modules/devices/kostal/kostal_piko_ci/counter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,50 @@
#!/usr/bin/env python3
from typing import TypedDict, Any

from modules.common.abstract_device import AbstractCounter
from modules.common.component_state import CounterState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType, ModbusTcpClient_
from modules.common.simcount import SimCounter
from modules.common.store import get_counter_value_store
from modules.devices.kostal.kostal_piko_ci.config import KostalPikoCiCounterSetup


class KwargsDict(TypedDict):
device_id: int
client: ModbusTcpClient_


class KostalPikoCiCounter(AbstractCounter):
def __init__(self, component_config: KostalPikoCiCounterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__device_id: int = self.kwargs['device_id']
self.client: ModbusTcpClient_ = self.kwargs['client']
self.store = get_counter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.sim_counter = SimCounter(self.__device_id, self.component_config.id, prefix="bezug")

def update(self) -> None:
unit = self.component_config.configuration.modbus_id

power = self.client.read_holding_registers(252, ModbusDataType.FLOAT_32, unit=unit)
powers = [self.client.read_holding_registers(
reg, ModbusDataType.FLOAT_32, unit=unit) for reg in [224, 234, 244]]
frequency = self.client.read_holding_registers(220, ModbusDataType.FLOAT_32, unit=unit)
imported, exported = self.sim_counter.sim_count(power)

counter_state = CounterState(
power=power,
powers=powers,
frequency=frequency,
imported=imported,
exported=exported,
)
self.store.set(counter_state)


component_descriptor = ComponentDescriptor(configuration_factory=KostalPikoCiCounterSetup)
50 changes: 50 additions & 0 deletions packages/modules/devices/kostal/kostal_piko_ci/device.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,50 @@
#!/usr/bin/env python3
import logging
from typing import Iterable, Union

from modules.common.abstract_device import DeviceDescriptor
from modules.common.component_context import SingleComponentUpdateContext
from modules.common.configurable_device import ConfigurableDevice, ComponentFactoryByType, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
from modules.devices.kostal.kostal_piko_ci.counter import KostalPikoCiCounter
from modules.devices.kostal.kostal_piko_ci.inverter import KostalPikoCiInverter
from modules.devices.kostal.kostal_piko_ci.config import (KostalPikoCi, KostalPikoCiCounterSetup,
KostalPikoCiInverterSetup)

log = logging.getLogger(__name__)


def create_device(device_config: KostalPikoCi):
client = None

def create_counter_component(component_config: KostalPikoCiCounterSetup):
nonlocal client
return KostalPikoCiCounter(component_config, device_id=device_config.id, client=client)

def create_inverter_component(component_config: KostalPikoCiInverterSetup):
nonlocal client
return KostalPikoCiInverter(component_config, device_id=device_config.id, client=client)

def update_components(components: Iterable[Union[KostalPikoCiCounter, KostalPikoCiInverter]]):
nonlocal client
with client:
for component in components:
with SingleComponentUpdateContext(component.fault_state):
component.update()

def initializer():
nonlocal client
client = ModbusTcpClient_(device_config.configuration.ip_address, device_config.configuration.port)

return ConfigurableDevice(
device_config=device_config,
initializer=initializer,
component_factory=ComponentFactoryByType(
counter=create_counter_component,
inverter=create_inverter_component,
),
component_updater=MultiComponentUpdater(update_components)
)


device_descriptor = DeviceDescriptor(configuration_factory=KostalPikoCi)
45 changes: 45 additions & 0 deletions packages/modules/devices/kostal/kostal_piko_ci/inverter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,45 @@
#!/usr/bin/env python3
from typing import TypedDict, Any

from modules.common.abstract_device import AbstractInverter
from modules.common.component_state import InverterState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType, ModbusTcpClient_
from modules.common.store import get_inverter_value_store
from modules.devices.kostal.kostal_piko_ci.config import KostalPikoCiInverterSetup


class KwargsDict(TypedDict):
device_id: int
client: ModbusTcpClient_


class KostalPikoCiInverter(AbstractInverter):
def __init__(self, component_config: KostalPikoCiInverterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.__device_id: int = self.kwargs['device_id']
self.client: ModbusTcpClient_ = self.kwargs['client']
self.store = get_inverter_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))

def update(self) -> None:
unit = self.component_config.configuration.modbus_id

power = self.client.read_holding_registers(172, ModbusDataType.FLOAT_32, unit=unit) * -1
currents = [self.client.read_holding_registers(
reg, ModbusDataType.FLOAT_32, unit=unit) for reg in [154, 160, 166]]
exported = self.client.read_holding_registers(320, ModbusDataType.FLOAT_32, unit=unit)

inverter_state = InverterState(
power=power,
currents=currents,
exported=exported
)
self.store.set(inverter_state)


component_descriptor = ComponentDescriptor(configuration_factory=KostalPikoCiInverterSetup)