66 changes: 34 additions & 32 deletions packages/control/bat_all.py
Original file line number Diff line number Diff line change
Expand Up @@ -291,40 +291,42 @@ def set_power_limit_controllable(self):

def get_power_limit(self):
if self.data.config.bat_control_permitted is False:
return
chargepoint_by_chargemodes = get_chargepoints_by_chargemodes(CONSIDERED_CHARGE_MODES_CHARGING)
# Falls aktive Steuerung an und Fahrzeuge laden und kein Überschuss im System ist,
# dann Speicherleistung begrenzen.
if (self.data.config.power_limit_mode != BatPowerLimitMode.NO_LIMIT.value and
len(chargepoint_by_chargemodes) > 0 and
data.data.cp_all_data.data.get.power > 100 and
self.data.get.power_limit_controllable and
self.data.get.power <= 0 and
data.data.counter_all_data.get_evu_counter().data.get.power >= -100):
if self.data.config.power_limit_mode == BatPowerLimitMode.LIMIT_STOP.value:
self.data.set.power_limit = 0
elif self.data.config.power_limit_mode == BatPowerLimitMode.LIMIT_TO_HOME_CONSUMPTION.value:
self.data.set.power_limit = data.data.counter_all_data.data.set.home_consumption * -1
log.debug(f"Speicher-Leistung begrenzen auf {self.data.set.power_limit/1000}kW")
else:
self.data.set.power_limit = None
control_range_low = data.data.general_data.data.chargemode_config.pv_charging.control_range[0]
control_range_high = data.data.general_data.data.chargemode_config.pv_charging.control_range[1]
control_range_center = control_range_high - (control_range_high - control_range_low) / 2
if len(chargepoint_by_chargemodes) == 0:
log.debug("Speicher-Leistung nicht begrenzen, "
"da keine Ladepunkte in einem Lademodus mit Netzbezug sind.")
elif data.data.cp_all_data.data.get.power <= 100:
log.debug("Speicher-Leistung nicht begrenzen, da kein Ladepunkt mit Netzbezug lädt.")
elif self.data.get.power_limit_controllable is False:
log.debug("Speicher-Leistung nicht begrenzen, da keine regelbaren Speicher vorhanden sind.")
elif self.data.get.power > 0:
log.debug("Speicher-Leistung nicht begrenzen, da kein Speicher entladen wird.")
elif data.data.counter_all_data.get_evu_counter().data.get.power < control_range_center + 80:
# Wenn der Regelbereich zB auf Bezug steht, darf auch die Leistung des Regelbereichs entladen werden.
log.debug("Speicher-Leistung nicht begrenzen, da EVU-Überschuss vorhanden ist.")
else:
chargepoint_by_chargemodes = get_chargepoints_by_chargemodes(CONSIDERED_CHARGE_MODES_CHARGING)
# Falls aktive Steuerung an und Fahrzeuge laden und kein Überschuss im System ist,
# dann Speicherleistung begrenzen.
if (self.data.config.power_limit_mode != BatPowerLimitMode.NO_LIMIT.value and
len(chargepoint_by_chargemodes) > 0 and
data.data.cp_all_data.data.get.power > 100 and
self.data.get.power_limit_controllable and
self.data.get.power <= 0 and
data.data.counter_all_data.get_evu_counter().data.get.power >= -100):
if self.data.config.power_limit_mode == BatPowerLimitMode.LIMIT_STOP.value:
self.data.set.power_limit = 0
elif self.data.config.power_limit_mode == BatPowerLimitMode.LIMIT_TO_HOME_CONSUMPTION.value:
self.data.set.power_limit = data.data.counter_all_data.data.set.home_consumption * -1
log.debug(f"Speicher-Leistung begrenzen auf {self.data.set.power_limit/1000}kW")
else:
log.debug("Speicher-Leistung nicht begrenzen.")
self.data.set.power_limit = None
control_range_low = data.data.general_data.data.chargemode_config.pv_charging.control_range[0]
control_range_high = data.data.general_data.data.chargemode_config.pv_charging.control_range[1]
control_range_center = control_range_high - (control_range_high - control_range_low) / 2
if len(chargepoint_by_chargemodes) == 0:
log.debug("Speicher-Leistung nicht begrenzen, "
"da keine Ladepunkte in einem Lademodus mit Netzbezug sind.")
elif data.data.cp_all_data.data.get.power <= 100:
log.debug("Speicher-Leistung nicht begrenzen, da kein Ladepunkt mit Netzbezug lädt.")
elif self.data.get.power_limit_controllable is False:
log.debug("Speicher-Leistung nicht begrenzen, da keine regelbaren Speicher vorhanden sind.")
elif self.data.get.power > 0:
log.debug("Speicher-Leistung nicht begrenzen, da kein Speicher entladen wird.")
elif data.data.counter_all_data.get_evu_counter().data.get.power < control_range_center + 80:
# Wenn der Regelbereich zB auf Bezug steht, darf auch die Leistung des Regelbereichs entladen
# werden.
log.debug("Speicher-Leistung nicht begrenzen, da EVU-Überschuss vorhanden ist.")
else:
log.debug("Speicher-Leistung nicht begrenzen.")
remaining_power_limit = self.data.set.power_limit
for bat_component in get_controllable_bat_components():
if self.data.set.power_limit is None:
Expand Down