38 changes: 7 additions & 31 deletions packages/modules/smarthome/avmhomeautomation/avmcommon.py
Original file line number Diff line number Diff line change
Expand Up @@ -42,9 +42,8 @@ def __init__(self):
if os.path.isfile(CACHEFILE):
self.logMessage(LOGLEVELDEBUG, "found an AVM cache file, trying to load")
try:
f = open(CACHEFILE, 'r')
self.cache = json.loads(f.read().strip())
f.close()
with open(CACHEFILE, 'r') as f:
self.cache = json.loads(f.read().strip())
except Exception as e:
self.logMessage(LOGLEVELDEBUG, "unable to load cache file: %s" % (e))

Expand All @@ -65,9 +64,8 @@ def writeCacheToRamdisk(self):
else:
cacheToWrite[login] = self.cache[login]
try:
f = open(CACHEFILE, 'w')
json.dump(cacheToWrite, f)
f.close()
with open(CACHEFILE, 'w') as f:
json.dump(cacheToWrite, f)
except Exception as e:
self.logMessage(LOGLEVELDEBUG, "unable to write cache file: %s" % (e))

Expand Down Expand Up @@ -166,28 +164,7 @@ def connect(self):

# logMessage writes a message to the logfile for the smarthome device.
def logMessage(self, level, message):
if level < self.loglevel:
return
now = time.localtime() # getstruct_time
time_string = time.strftime("%Y-%m-%d %H:%M:%S", now)
logfile_string = '/var/www/html/openWB/ramdisk/smarthome.log'
try:
if os.path.isfile(logfile_string):
f = open(logfile_string, 'a', encoding='utf8')
else:
f = open(logfile_string, 'w', encoding='utf8')
prefix = ""
if level == LOGLEVELDEBUG:
prefix = "[DEBUG] "
if level == LOGLEVELINFO:
prefix = "[INFO] "
if level == LOGLEVELERROR:
prefix = "[ERROR] "
log.debug('%s: (%s) AVM (actor: %s) %s%s' %
(time_string, self.devicenumber, self.switchname, prefix, message), file=f)
f.close()
except IOError:
pass
log.debug(f'({self.devicenumber}) AVM (actor: {self.switchname}) {message}')

# getDevicesDict returns a dictionary that maps defined actor names to its
# unique hardware ID (called "AIN": "Actuator Identification Number") and
Expand Down Expand Up @@ -362,9 +339,8 @@ def getActualPower(self):
outFileString = '/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(self.devicenumber)
self.logMessage(LOGLEVELDEBUG, "handing answer back to smarthomehandler via %s" % (outFileString))
try:
f1 = open(outFileString, 'w')
json.dump(answer, f1)
f1.close()
with open(outFileString, 'w') as f1:
json.dump(answer, f1)
except IOError as e:
self.logMessage(LOGLEVELERROR, "error writing power result %s" % (e))
log.debug(answer) # dump answer to stdout if file cannot be written
Expand Down
8 changes: 4 additions & 4 deletions packages/modules/smarthome/fronius/watt.py
Original file line number Diff line number Diff line change
@@ -1,9 +1,12 @@
#!/usr/bin/python3
import logging
import sys
import json
import jq
import urllib.request

log = logging.getLogger(__name__)

devicenumber = str(sys.argv[1])
ipadr = str(sys.argv[2]) # IP-ADresse des Fronius Wechselrichters, mit dem der Zähler kommuniziert
smid = int(sys.argv[3]) # ID des Zählers im Wechselrichter (Hauptzähler 0, weitere fortlaufend)
Expand All @@ -27,7 +30,4 @@
except Exception:
powerc = 0

f1 = open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w')
answer = '{"power":' + str(power) + ',"powerc":' + str(powerc) + '}'
json.dump(answer, f1)
f1.close()
log.debug("Device" + str(devicenumber) + '{"power":' + str(power) + ',"powerc":' + str(powerc) + '}')
8 changes: 4 additions & 4 deletions packages/modules/smarthome/json/watt.py
Original file line number Diff line number Diff line change
@@ -1,9 +1,12 @@
#!/usr/bin/python3
import logging
import sys
import json
import jq
import urllib.request

log = logging.getLogger(__name__)

devicenumber = str(sys.argv[1])
# Abfrage-URL, die die .json Antwort liefert. Z.B.
# "http://192.168.0.150/solar_api/v1/GetMeterRealtimeData.cgi?Scope=Device&DeviceID=1"
Expand All @@ -26,7 +29,4 @@
except Exception:
powerc = 0

f1 = open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w')
answer = '{"power":' + str(power) + ',"powerc":' + str(powerc) + '}'
json.dump(answer, f1)
f1.close()
log.debug('Device' + str(devicenumber) + '{"power":' + str(power) + ',"powerc":' + str(powerc) + '}')
5 changes: 2 additions & 3 deletions packages/modules/smarthome/mqtt/off.py
Original file line number Diff line number Diff line change
Expand Up @@ -35,6 +35,5 @@ def on_message(client, userdata, msg) -> None:
client.disconnect()
file_stringpv = '/var/www/html/openWB/ramdisk/smarthome_device_' + str(devicenumber) + '_pv'
pvmodus = 0
f = open(file_stringpv, 'w')
f.write(str(pvmodus))
f.close()
with open(file_stringpv, 'w') as f:
f.write(str(pvmodus))
5 changes: 2 additions & 3 deletions packages/modules/smarthome/mqtt/on.py
Original file line number Diff line number Diff line change
Expand Up @@ -34,6 +34,5 @@ def on_message(client, userdata, msg) -> None:
client.loop(timeout=2.0)
client.disconnect()
file_stringpv = '/var/www/html/openWB/ramdisk/smarthome_device_' + str(devicenumber) + '_pv'
f = open(file_stringpv, 'w')
f.write(str(1))
f.close()
with open(file_stringpv, 'w') as f:
f.write(str(1))
5 changes: 2 additions & 3 deletions packages/modules/smarthome/mqtt/watt.py
Original file line number Diff line number Diff line change
Expand Up @@ -69,9 +69,8 @@ def on_message(client, userdata, msg) -> None:
# PV-Modus
pvmodus = 0
if os.path.isfile(file_stringpv):
f = open(file_stringpv, 'r')
pvmodus = int(f.read())
f.close()
with open(file_stringpv, 'r') as f:
pvmodus = int(f.read())
answer = '{"power":' + str(aktpower) + ',"powerc":' + str(powerc)
answer += ',"on":' + str(pvmodus) + ',"temp0":' + str(tempa)
answer += ',"temp1":' + str(tempb) + ',"temp2":' + str(tempc) + '}'
Expand Down
8 changes: 5 additions & 3 deletions packages/modules/smarthome/mystrom/watt.py
Original file line number Diff line number Diff line change
@@ -1,9 +1,12 @@
#!/usr/bin/python3
import logging
import sys
import time
import json
import urllib.request

log = logging.getLogger(__name__)

named_tuple = time.localtime() # getstruct_time
time_string = time.strftime("%m/%d/%Y, %H:%M:%S mystrom watty.py", named_tuple)
devicenumber = str(sys.argv[1])
Expand All @@ -21,6 +24,5 @@
powerc = 0
answer = '{"power":' + str(aktpower) + ',"powerc":' + str(powerc) + ',"on":' + \
str(relais) + ',"temp0":' + str(temp) + '} '
f1 = open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w')
json.dump(answer, f1)
f1.close()
with open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w') as f1:
log.debug('Device' + str(devicenumber) + ' ' + answer)
5 changes: 2 additions & 3 deletions packages/modules/smarthome/nibe/watt.py
Original file line number Diff line number Diff line change
Expand Up @@ -29,8 +29,7 @@
CurrentPower = None # Handle error case

answer = '{"power":' + str(CurrentPower) + '}'
f1 = open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w')
json.dump(answer, f1)
f1.close()
with open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w') as f1:
json.dump(answer, f1)

client.close() # clean disconnect from modbus server
55 changes: 24 additions & 31 deletions packages/modules/smarthome/smaem/watt.py
Original file line number Diff line number Diff line change
Expand Up @@ -33,7 +33,6 @@
import os
import datetime
import time
import json
import signal
import socket
import struct
Expand Down Expand Up @@ -68,7 +67,7 @@ def abortprogram(signal, frame):
timefile = '/var/www/html/openWB/ramdisk/smarthome_device_ret' + \
str(devicenumber) + '_time' # Dummy file needed for timestamp of last metering
# Logfile for additional output beside of the smarthome.log
debugfile = open('/var/www/html/openWB/ramdisk/smaem.log', 'a', newline='\r\n')


sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM, socket.IPPROTO_UDP)
sock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
Expand Down Expand Up @@ -108,18 +107,18 @@ def abortprogram(signal, frame):
"HomeManager (2) is sending in the network.")

emparts = decode_speedwire(sock_data)
debugfile.write(str(datetime.datetime.now()) + ': smaserial: #' + str(smaserial) + '# - Current SMA serial number:#' +
str(emparts['serial']) + '# - watt:#' + str(int(emparts.get("pconsume"))) + '# - wattc:#' +
str("{:.3f}".format(int(emparts.get('pconsumecounter')*1000))) + '#\n')
log.debug('SMA:: smaserial: #' + str(smaserial) + '# - Current SMA serial number:#' +
str(emparts['serial']) + '# - watt:#' + str(int(emparts.get("pconsume"))) + '# - wattc:#' +
str("{:.3f}".format(int(emparts.get('pconsumecounter')*1000))) + '#')

# Remember: We assume that beside of our EnergyMeter there are more SMA devices present (like HomeManager 2.0 or other
# EnergyMeter) - so must not accept any data or smaserial = None
if str(emparts['serial']) == str(smaserial): # Scenario 1: Our EnergyMeter is sending, so we put the current values in
# our output variables
watt = str(int(emparts.get("pconsume")))
wattc = str("{:.3f}".format(int(emparts.get('pconsumecounter')*1000)))
debugfile.write(str(datetime.datetime.now()) + ': 1 - Our SMA EM ' + str(smaserial) +
' is sending, everything fine. watt: #' + str(watt) + '# - wattc: #' + str(wattc) + '#\n')
log.debug('SMA:: 1 - Our SMA EM ' + str(smaserial) +
' is sending, everything fine. watt: #' + str(watt) + '# - wattc: #' + str(wattc) + '#')
# Scenario 2: Our EnergyMeter is not sending but we have a returnfile which is older than n seconds (parameter
# secondssincelastmetering)
elif ((os.path.isfile(returnfile)) and
Expand All @@ -128,29 +127,27 @@ def abortprogram(signal, frame):
# We set "0" as current Power Consume (pconsume) and (from the existing ret-file) the last value for the Power
# Consume Counter (pconsumecounter)
watt = '0'
ret = open(returnfile, 'r')
lastvalues = ret.read()
ret.close()
with open(returnfile, 'r') as ret:
lastvalues = ret.read()
timesincelastmetering = int(round(time.time(), 0)-lastmodificationtime)
wattc = lastvalues[int(lastvalues.rfind('powerc')) + 9:lastvalues.find('}')]
debugfile.write(str(datetime.datetime.now()) + ': 2 - Debug: time.time(): #' + str(round(time.time(), 0)) +
'# - lastmodificationtime: #' + str(lastmodificationtime) +
'# - timesincelastmetering: #' + str(timesincelastmetering) +
'# - int(secondssincelastmetering): #' + str(int(secondssincelastmetering)) + '#\n')
debugfile.write(str(datetime.datetime.now()) + ': 2 - We create a fake ret-file. watt: #' + str(watt) +
'# - wattc: #' + str(
log.debug('SMA:: 2 - Debug: time.time(): #' + str(round(time.time(), 0)) +
'# - lastmodificationtime: #' + str(lastmodificationtime) +
'# - timesincelastmetering: #' + str(timesincelastmetering) +
'# - int(secondssincelastmetering): #' + str(int(secondssincelastmetering)) + '#')
log.debug('SMA:: 2 - We create a fake ret-file. watt: #' + str(watt) +
'# - wattc: #' + str(
wattc) + '# - lastvalues: #' + lastvalues + '# - int-lastvalues.rfind-powerc: #' +
str((lastvalues.rfind('powerc'))) + '#\n')
str((lastvalues.rfind('powerc'))) + '#')

# Scenario 3: Our EnergyMeter is not sending but we have a returnfile which is younger than n seconds
# (parameter secondssincelastmetering)
elif ((os.path.isfile(returnfile)) and
(int((round(time.time(), 0)-lastmodificationtime)) < int(secondssincelastmetering))):
# We have a ret-file which is younger than n seconds. We do nothing as the existing ret-file is good enough.
debugfile.write(str(datetime.datetime.now()) +
': 3 - The existing ret-file is fine enough. round(time.time(),0): #' + str(round(time.time(), 0))
+ '# - lastmodificationtime: #' + str(lastmodificationtime) + '# - secondssincelastmetering: #'
+ str(secondssincelastmetering) + '#\n')
log.debug('SMA:: 3 - The existing ret-file is fine enough. round(time.time(),0): #' + str(round(time.time(), 0))
+ '# - lastmodificationtime: #' + str(lastmodificationtime) + '# - secondssincelastmetering: #'
+ str(secondssincelastmetering) + '#')
sys.exit("Module SMAEM: No data received but we have historical data which is younger than " +
str(secondssincelastmetering) + " seconds.")
else:
Expand All @@ -162,20 +159,16 @@ def abortprogram(signal, frame):
# Module SMAEM: No data received and no historical data since boot time
# Leistungsmessung smaem [...] Fehlermeldung: [Errno 2] No such file or directory:
# '/var/www/html/openWB/ramdisk/smarthome_device_ret1'
debugfile.write(str(datetime.datetime.now()) + ': 4 - No data received and no historical data since boottime\n')
log.debug('SMA:: 4 - No data received and no historical data since boottime')
sys.exit(str(datetime.datetime.now()) + ": Module SMAEM: No data received and no historical data since boottime")

# General output section

answer = '{"power":' + watt + ',"powerc":' + wattc + '}'
f = open(returnfile, 'w')
json.dump(answer, f)
f.close()

t = open(timefile, 'w')
t.write(str(datetime.datetime.now()) +
': File is created by Smarthome module SMAEM for validating the timestamp of the last return-file creation.')
t.close()
with open(timefile, 'w') as t:
t.write(str(datetime.datetime.now()) +
': File is created by Smarthome module SMAEM for validating '
'the timestamp of the last return-file creation.')

debugfile.write(str(datetime.datetime.now()) + ': 99 - Output answer: #' + answer + '#\n')
debugfile.close()
log.debug('SMA:: 99 - Output answer: #' + answer + '#')
5 changes: 2 additions & 3 deletions packages/modules/smarthome/tasmota/watt.py
Original file line number Diff line number Diff line change
Expand Up @@ -26,6 +26,5 @@
relais = 1
powerc = 0
answer = '{"power":' + str(aktpower) + ',"powerc":' + str(powerc) + ',"on":' + str(relais) + '} '
f1 = open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w')
json.dump(answer, f1)
f1.close()
with open('/var/www/html/openWB/ramdisk/smarthome_device_ret' + str(devicenumber), 'w') as f1:
json.dump(answer, f1)
26 changes: 7 additions & 19 deletions packages/modules/smarthome/viessmann/off.py
Original file line number Diff line number Diff line change
@@ -1,14 +1,10 @@
#!/usr/bin/python3
import sys
import os
import time
from pymodbus.client.sync import ModbusTcpClient
import logging

log = logging.getLogger(__name__)

named_tuple = time.localtime() # getstruct_time
time_string = time.strftime("%m/%d/%Y, %H:%M:%S viessmann off.py", named_tuple)
devicenumber = str(sys.argv[1])
ipadr = str(sys.argv[2])
uberschuss = int(sys.argv[3])
Expand All @@ -22,22 +18,14 @@
# coils read write boolean
# register start 00000
#
file_string = '/var/www/html/openWB/ramdisk/smarthome_device_' + str(devicenumber) + '_viessmann.log'
file_stringpv = '/var/www/html/openWB/ramdisk/smarthome_device_' + str(devicenumber) + '_pv'
if os.path.isfile(file_string):
f = open(file_string, 'a')
else:
f = open(file_string, 'w')
log.debug('%s devicenr %s ipadr %s ueberschuss %6d try to connect (modbus)' %
(time_string, devicenumber, ipadr, uberschuss), file=f)
log.debug(f"[Viessmann {devicenumber}] devicenr {devicenumber} ipadr {ipadr} "
f"ueberschuss {uberschuss:6d} try to connect (modbus)")
client = ModbusTcpClient(ipadr, port=502)
rq = client.write_coil(16, False, unit=1)
log.debug(rq, file=f)
log.debug(f"[Viessmann {devicenumber}] Modbus write_coil response: {rq}")
client.close()
log.debug('%s devicenr %s ipadr %s Einmalige Warmwasseraufbereitung deaktiviert CO-17 = 0 ' %
(time_string, devicenumber, ipadr), file=f)
f.close()
log.debug(
f"[Viessmann {devicenumber}] devicenr {devicenumber} ipadr {ipadr} "
"Einmalige Warmwasseraufbereitung deaktiviert CO-17 = 0")
pvmodus = 0
f = open(file_stringpv, 'w')
f.write(str(pvmodus))
f.close()
log.debug(f"[Viessmann {devicenumber}] PV-Modus gesetzt: {pvmodus}")
27 changes: 8 additions & 19 deletions packages/modules/smarthome/viessmann/on.py
Original file line number Diff line number Diff line change
@@ -1,14 +1,10 @@
#!/usr/bin/python3
import sys
import os
import time
from pymodbus.client.sync import ModbusTcpClient
import logging

log = logging.getLogger(__name__)

named_tuple = time.localtime() # getstruct_time
time_string = time.strftime("%m/%d/%Y, %H:%M:%S viessmann on.py", named_tuple)
devicenumber = str(sys.argv[1])
ipadr = str(sys.argv[2])
uberschuss = int(sys.argv[3])
Expand All @@ -24,21 +20,14 @@
# coils read write boolean
# register start 00000
#
file_string = '/var/www/html/openWB/ramdisk/smarthome_device_' + str(devicenumber) + '_viessmann.log'
file_stringpv = '/var/www/html/openWB/ramdisk/smarthome_device_' + str(devicenumber) + '_pv'
if os.path.isfile(file_string):
f = open(file_string, 'a')
else:
f = open(file_string, 'w')
log.debug('%s devicenr %s ipadr %s ueberschuss %6d try to connect (modbus)' %
(time_string, devicenumber, ipadr, uberschuss), file=f)
log.debug(
f"[Viessmann {devicenumber}] devicenr {devicenumber} ipadr {ipadr} "
f"ueberschuss {uberschuss:6d} try to connect (modbus)")
client = ModbusTcpClient(ipadr, port=502)
rq = client.write_coil(16, True, unit=1)
log.debug(rq, file=f)
log.debug(f"[Viessmann {devicenumber}] Modbus write_coil response: {rq}")
client.close()
log.debug('%s devicenr %s ipadr %s Einmalige Warmwasseraufbereitung aktiviert CO-17 = 1' %
(time_string, devicenumber, ipadr), file=f)
f.close()
f = open(file_stringpv, 'w')
f.write(str(1))
f.close()
log.debug(
f"[Viessmann {devicenumber}] devicenr {devicenumber} ipadr {ipadr} "
"Einmalige Warmwasseraufbereitung aktiviert CO-17 = 1")
log.debug(f"[Viessmann {devicenumber}] PV-Modus gesetzt: 1")
Loading