31 changes: 23 additions & 8 deletions packages/modules/common/sdm.py
Original file line number Diff line number Diff line change
Expand Up @@ -35,11 +35,13 @@ class SdmRegister(IntEnum):


class Sdm630_72(Sdm):
REG_MAPPING = (
REG_MAPPING_BULK_1 = (
(SdmRegister.VOLTAGE_L1, [ModbusDataType.FLOAT_32]*3),
(SdmRegister.CURRENT_L1, [ModbusDataType.FLOAT_32]*3),
(SdmRegister.POWER_L1, [ModbusDataType.FLOAT_32]*3),
(SdmRegister.POWER_FACTOR_L1, [ModbusDataType.FLOAT_32]*3),
(SdmRegister.POWER_FACTOR_L1, [ModbusDataType.FLOAT_32]*3)
)
REG_MAPPING_BULK_2 = (
(SdmRegister.FREQUENCY, ModbusDataType.FLOAT_32),
(SdmRegister.IMPORTED, ModbusDataType.FLOAT_32),
(SdmRegister.EXPORTED, ModbusDataType.FLOAT_32),
Expand All @@ -57,8 +59,14 @@ def get_power(self) -> Tuple[List[float], float]:
return powers, power

def get_counter_state(self) -> CounterState:
resp = self.client.read_input_registers_bulk(
SdmRegister.VOLTAGE_L1, 76, mapping=self.REG_MAPPING, unit=self.id)
# entgegen der Doku können nicht bei allen SDM72 80 Register auf einmal gelesen werden,
# manche können auch nur 50
bulk_1 = self.client.read_input_registers_bulk(
SdmRegister.VOLTAGE_L1, 38, mapping=self.REG_MAPPING_BULK_1, unit=self.id)
time.sleep(0.1)
bulk_2 = self.client.read_input_registers_bulk(
SdmRegister.FREQUENCY, 8, mapping=self.REG_MAPPING_BULK_2, unit=self.id)
resp = {**bulk_1, **bulk_2}
frequency = resp[SdmRegister.FREQUENCY]
if frequency > 100:
frequency = frequency / 10
Expand All @@ -78,11 +86,13 @@ def get_counter_state(self) -> CounterState:


class Sdm120(Sdm):
REG_MAPPING = (
REG_MAPPING_BULK_1 = (
(SdmRegister.VOLTAGE_L1, ModbusDataType.FLOAT_32),
(SdmRegister.CURRENT_L1, ModbusDataType.FLOAT_32),
(SdmRegister.POWER_L1, ModbusDataType.FLOAT_32),
(SdmRegister.POWER_FACTOR_L1, ModbusDataType.FLOAT_32),
(SdmRegister.POWER_FACTOR_L1, ModbusDataType.FLOAT_32)
)
REG_MAPPING_BULK_2 = (
(SdmRegister.FREQUENCY, ModbusDataType.FLOAT_32),
(SdmRegister.IMPORTED, ModbusDataType.FLOAT_32),
(SdmRegister.EXPORTED, ModbusDataType.FLOAT_32),
Expand All @@ -99,8 +109,13 @@ def get_power(self) -> Tuple[List[float], float]:
return [power, 0, 0], power

def get_counter_state(self) -> CounterState:
resp = self.client.read_input_registers_bulk(
SdmRegister.VOLTAGE_L1, 76, mapping=self.REG_MAPPING, unit=self.id)
# beim SDM120 steht nichts von Bulk-Reads in der Doku, daher auch auf 50 Register limitiert
bulk_1 = self.client.read_input_registers_bulk(
SdmRegister.VOLTAGE_L1, 32, mapping=self.REG_MAPPING_BULK_1, unit=self.id)
time.sleep(0.1)
bulk_2 = self.client.read_input_registers_bulk(
SdmRegister.FREQUENCY, 8, mapping=self.REG_MAPPING_BULK_2, unit=self.id)
resp = {**bulk_1, **bulk_2}
frequency = resp[SdmRegister.FREQUENCY]
if frequency > 100:
frequency = frequency / 10
Expand Down